Basic Installation Procedures
975-0822-01-01
37
Testing in Grid Mode
To test the Freedom X:
n
With the test load from the previous test still connected and
operating, connect the shore power source.
n
The Freedom X transfers the test load to shore power. The
green LED indicating grid mode turns on and the LCD screen
displays the
AC MODE
icon.
n
If the test load operates, your installation is successful.
NOTE
: If the Power button on the Freedom X is turned ON, the
Freedom X will automatically supply the appliances with inverter
power if the shore power source fails or becomes disconnected.
If the Power button on the Freedom X is turned ON and shore
power voltage is too low (less than 90 V
V
), the unit will transfer
to inverter power to continue running your appliances.
NOTE
: Whether or not the Power button is turned ON, shore
power will pass through the Freedom X to the output when shore
power is within normal operating range.
NOTE
: In the event of low or no battery voltage, shore power will
pass through the Freedom X to the output even when shore power
is outside the normal operating range.
Содержание Freedom X 2000
Страница 1: ...Freedom X 2000 230V Inverter Owner s Guide Freedom X 2000 230V 817 2000 12...
Страница 12: ...This page is intentionally left blank 2...
Страница 24: ...This page is intentionally left blank 2...
Страница 52: ...This page is intentionally left blank 2...
Страница 77: ...This page is intentionally left blank 2...
Страница 91: ...This page is intentionally left blank 2...