975-0545-01-01
59
Battery Charging Referen
c
e
The numbers presented in these tables are base numbers only and will vary
with factors such as temperature compensation and battery type.
Table 11
Battery Current Defaults
Current
Flooded
(or wet)
Gel
AGM
I
B
Bulk
Current
(ADC)
20% Ah
20% Ah
20% Ah
I
H
Absorption
Exit Current
(ADC)
2% Ah
2% Ah
2% Ah
I
E
Equalize
Current
(ADC)
10% Ah
NA
NA
I
B
Bulk
Current
(ADC)
20% Ah
20% Ah
20% Ah
I
H
Absorption
Exit Current
(ADC)
2% Ah
2% Ah
2% Ah
I
E
Equalize
Current
(ADC)
10% Ah
NA
NA
Table 12
Battery Time Defaults
Time
Flooded
(or wet)
Gel
AGM
Δ
T
A
Absorption
Timeout
(hours)
6
6
6
Δ
T
CV
Constant
Voltage
Absorption
Timeout
(hours)
1
1
1
Δ
T
F
Float
Timeout
(days)
7
7
7
Δ
T
E
Equalize
Timeout
(hours)
1
NA
NA
IMPORTANT:
The custom battery factory defaults are the same as for an
AGM battery.