background image

 

The LEDflashesred 

and green 3 times 

sequentially every 4 

seconds.

 

3 long beeps 

every 4 

seconds.

 

Dangeroussmoke 

concentration is detected by 

the initiating unit in the 

network. Please find the 

initiating unit and take 

action.

 

Unit that detects 

CO (alarm not 

initiated). 

 

A CO concentration 

level ranging from 30 

to 999 ppm has been 

detected, but for less 

than the allotted 

detection period. The 

green LED indicator 

flashes once every 60 

seconds. 

 

None.

 

Dangerous CO concentration   

is detected, but has not 

reached the alarm status. 

Potentially dangerous CO 

conditions exist. 

 

Please search for the CO 

source first. Open nearby 

windows and doors, and 

immediately move to fresh 

air. 

 

Unit that 

detected CO and 

initiated an 

alarm. 

None. 

The LED indicator 

flashes green once 

every second for 5 

seconds. 

None. 

Alarm cancellation: when 

the CO concentration level 

drops below the alarm 

threshold, the alarm signal 

will stop. 

Test 

Mode 

Test a single 

unit.

 

 

 

2 sets of 4 red 

flashes. 

 

2 sets of 4 quick 

beeps. 

 

Press the Test/Silence 

button. 

 

Peak CO level recorded 

since the previous reset.

 

Test all 

interconnected 

units.

 

 

The LED indicator 

flashes red rapidly. 

 

Continuous 

beeping until 

you release the 

Test/Silence 

button. 

Initiatingalarm. 

Hold down the Test/Silence   

button on one unit in the 

network.

 

 

The LEDflashes red 

and green 

sequentially.

 

Other interconnected alarms 

in the network.

 

Silence Mode 

 

 

The LED indicator 

flashesred 4 times 

every 5.8 seconds. 

None.

 

CO silence mode: After 9 

minutes, the unit will exit 

silence mode.

 

Содержание XC01-WR

Страница 1: ...X SENSE XC01 WR Wireless Interlinked Carbon Monoxide Alarm UL 2034 Email support x sense com...

Страница 2: ...e note that this device does not detect smoke heat flames or anyhazardous gas other than carbon monoxide even though carbonmonoxide can be generated by fire For this reason you mustinstall smoke alarm...

Страница 3: ...as begun the alarm will sound and the LED indicator will flash red This does not indicate that CO is present If you press the test button during an alarm state the unit will enter the silence mode CO...

Страница 4: ...urs WARNING THIS DEVICE IS DESIGNED TO PROTECT INDIVIDUALS FROM ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A...

Страница 5: ...wirelessly interlinked with other X Sense Link alarms but is not designed to communicate with wirelessinterlinked alarms from other manufacturers The X Sense Link wirelessinterlinked alarms in one mul...

Страница 6: ...it will beep once and the LED will flash red slowly indicating it is ready to add a new device to the network Next quickly press the test silence button on the new unit twice and the LED will flash re...

Страница 7: ...network or added to a new network NOTE The X Sense Link wirelessinterlinked alarms in one multi pack have already been interconnected To create a new network you will first need to disconnect each ala...

Страница 8: ...hould have a horizontal distance between 3 3 feet 1 m and 10 feet 3 m from any potential CO source If there is a partition in the room the CO alarm should be installed on the same side of the partitio...

Страница 9: ...alarm To avoid causing damage to the unit to provide optimum performance and to prevent unnecessary nuisance alarms do not locate CO alarms in the following areas 1 In garages or in any extremely dust...

Страница 10: ...ts or open windows Excessive air flow may prevent any CO from reaching the sensors 9 In direct sunlight 10 Near large metal surfaces or where there are lots of cables or wires that can cause interfere...

Страница 11: ...Remove the indication sticker from the packaging and refer to the hole locations on the sticker Draw two screw holes according to the size and layout of the mounting holes on the back of the product...

Страница 12: ...re to the recommended placement as described in Where to Install Alarm Testing Be sure to test your CO alarms when you turn them on for the first time or if the group configuration has changed In addi...

Страница 13: ...circuit without the need totest with CO If your CO alarm fails to emit an audible test signal refer to the troubleshooting guide at the end of this manual immediately Peak CO Concentration Memory and...

Страница 14: ...ected units will sound If the smoke alarm and CO alarm are triggered in the network at the same time the alarm signal of the smoke alarm will take priority over that of the CO alarm This alarm has a r...

Страница 15: ...itiates an alarm A CO concentration ranging from 30 to 999 ppm has been present for a certain time period The blue backlight is lit and the LED indicator flashes red4 times every 5 8 seconds 4 quick b...

Страница 16: ...ately move to fresh air Unit that detected CO and initiated an alarm None The LED indicator flashes green once every second for 5 seconds None Alarm cancellation when the CO concentration level drops...

Страница 17: ...yellow twice every 60 seconds 2 beeps every 60 seconds Please clean youralarm and see if it is working normally If Err continuesto display the unit has malfunctioned and must be replaced immediately E...

Страница 18: ...lified appliance technician to investigate sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment 4 If problems are identified during this inspecti...

Страница 19: ...through 8 cycles yellow green red Reinstall your alarm and test it by pressing the Test Silence button Note Rechargeable batteries are not recommended for use with this device Limitations of CO Alarm...

Страница 20: ...ring impaired 5 CO alarms are not a substitute for a smoke alarm Although fire is a source of carbon monoxide this CO alarm does not sense smoke or fire This CO alarm senses CO that may be escaping un...

Страница 21: ...harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harm...

Страница 22: ...th household waste Please recycle where facilities exist Check with Local Authority or retailer for recycling advice Manufacturer and Service Information X Sense Innovations Co Ltd Address B4 503 Kexi...