ITALIANO
5. PROGRAMMAZIONE
RITARDO ALLARME
OFF
OFF
ESCLUDE IL RITARDO
ALLARME
RITARDO ALLARME
OFF
RITARDO ALLARME
1 min
SERVE AD IMPOSTARE IL
RITARDO SULL’ATTIVAZIONE
DELL’USCITA DI ALLARME
RANGE 1 ÷ 250min
PULSANTE MANUALE
INSTABILE
PULSANTE MANUALE
INSTABILE
INSTABILE
AVVIA IL MOTORE
SOLO DURANTE LA PRESSIONE
SUL PULSANTE
MAN
PULSANTE MANUALE
STABILE
STABILE
AVVIA IL MOTORE CON UN
IMPULSO SUL PULSANTE
MAN;
ARRESTA IL MOTORE CON UN
IMPULSO SUL PULSANTE
RESET
ATTESA PRESENZA
RETE OFF
OFF
ESCLUDE L’ATTESA
PRESENZA RETE
ATTESA PRESENZA
RETE OFF
ATTESA PRESENZA
RETE 1 min
SERVE AD IMPOSTARE
L’ATTESA PRESENZA RETE
RANGE 1 ÷ 30min
TENSIONE MINIMA
207 V
TENSIONE MINIMA
207 V
SERVE AD IMPOSTARE LA
TENSIONE DI FUNZIONAMENTO
MINIMA DEI MOTORI
RANGE 180 ÷ 220V (SA694.xx)
RANGE 340 ÷ 380V (SA697.xx)
TENSIONE MASSIMA
253 V
TENSIONE MASSIMA
253 V
SERVE AD IMPOSTARE LA
TENSIONE DI FUNZIONAMENTO
MASSIMA DEI MOTORI
RANGE 230 ÷ 253V (SA694.xx)
RANGE 400 ÷ 440V (SA697.xx)
TENSIONE MINIMA
OFF
TENSIONE MASSIMA
OFF
OFF
ESCLUDE IL CONTROLLO
SULLA TENSIONE MINIMA
OFF
ESCLUDE IL CONTROLLO
SULLA TENSIONE MASSIMA
PREMUTO PER PIÚ DI 1s SI ESCE
DAL SETUP E SI SALVANO I
PARAMETRI IN MEMORIA
PREMUTO SI RITORNA ALLA PRIMA
SCHERMATA DEL SETUP;
VEDI CAPITOLO 5.1
13