background image

7.  Always  ensure  that  the  power  supply  to  your  laser  is  properly 
grounded before use.

8. 

DO  NOT  USE

 this fixture if you suspect that it contains a defect of any 

kind either  from  manufacturing, damage,  general  wear  or  has  a  broken 
manufacturer’s  seal. Return  the  fixture to  the  factory  for  service and/or 
maintenance immediately. 

9.  Some lasers  are  capable of  starting  fires  at great distances. Do not 
use  this  product  around  or  in  a  path  to  any  combustible  or  otherwise 
flammable materials. Use caution. 

10.  Before  using  this  product  in  any  capacity,  ensure  that  the  unit  is 
properly secured to prevent accidental beam  shifts  and that a  safety ca-
ble is used for any aerial rigging. 

11. Blue color  lasers  must be used with special care because the wave-
length  is in  the hazard zone  for  photo-toxicity also known  as  the  'blue 
effect'.  This  wavelength  can  cause  injury  well  below  the  thermal  MPE 
levels. Using this product as specified herein  and as  required by a  vari-
ance will virtually eliminate this hazard.

12. This product is not a toy and should be kept inaccessible to unauthor-
ized  persons  before,  during,  and  after  use.  Authorized  persons  should 
only  be  employees  of  an  FDA  variance  holder.  Keep   away  from 
minors.***

13.  This  unit  should  never  be  left  unattended  while  operational  and 
should  always  be  unplugged  from  both  DMX  and  power  while  being 
transported, rigged, de-rigged,  cleaned as  described  below,  or  when  a 
qualified operator is not present. We also recommend keeping your DMX 
controller  separate  from  the  laser  at  all  times  to  prevent  unwanted 
activation.*** 

14. Before using this product, it is the responsibility of the user  to be fa-
miliar with all Federal and State reporting and usage requirements. Laws 
vary by state. Keep  all body parts  and clothing away from the laser, and 
particularly the aperture at ALL times. 

15.  Do  not  stand  in  front  of  the  laser  while active. All  persons  should 
wear  protective eyewear while rigging, maintaining, or otherwise working 
with  the laser. Loose clothing or  long hair could get caught in the moving 
mirrors or beams and should be avoided. 

16.  Failure  to follow  the above  precautions  and other  precautions  con-
tained in this user manual, particularly with  regard to human exposure to 
laser  radiation  and electrical  safety, may result  in  serious  injury,  loss of 
vision, electric  shock, skin  damage, and death. Please refer  to the sec-

Page 6   of 18

Содержание X-Pod

Страница 1: ...ping this manual with your new laser fixture at all times both as a laser safety reference and a field refer ence for DMX operation DMX charts are included for your convenience To use the full capabil...

Страница 2: ...uidelines for Proper Usage 8 Temperature and Lasers 9 Getting Started 9 Unpacking 9 Installation 10 Hanging your lasers 10 STOP CAUTION 10 X Pod Operating Modes 10 Sound Active 11 Auto Mode 11 DMX Mod...

Страница 3: ...ions about proper use of these laser systems laser safety troubleshooting or anything else visit us on our web site 24 7 at www x laser com so that we can best assist you We want you to have a wonderf...

Страница 4: ...s product ac knowledges that they have been advised that an FDA variance is re quired prior to use of any Class IIIB or IV laser system and the purchaser certifies that this product will only be opera...

Страница 5: ...ari ance or using an illegal laser are significant 3 Do not expose the human eye directly or indirectly to focused or scat tered laser radiation as loss of vision complete blindness and or other serio...

Страница 6: ...s before during and after use Authorized persons should only be employees of an FDA variance holder Keep away from minors 13 This unit should never be left unattended while operational and should alwa...

Страница 7: ...be opened by the user To ensure proper safe operation in demonstrations and performances please im mediately discontinue use of your X Laser product if you notice or sus pect that any part of the las...

Страница 8: ...procedures and or do not know how to use all components of a DMX system properly Blue Light Hazard For X Laser products which contain blue or blue violet lasers there is a special issue which must be...

Страница 9: ...best at room temperature with colder and warmer tempera tures resulting in inconsistent performance Always ensure that the laser housing has excellent airflow around the case and that the air is no co...

Страница 10: ...hat your DMX programming is suitable for the new orientation and will result in safe operation STOP CAUTION Before powering on the laser be sure that you have a minimum of 3 meters clearance from any...

Страница 11: ...n order and patterns will change at four frames per second which is very near an eight note of a 120 BPM song The X Pod Router has two automatic modes Standard Automatic Mode The Router cycles through...

Страница 12: ...6 183 Squiggle Left 56 63 Double Right 184 191 Squiggle Back and Forth 64 71 Double Left 192 199 Individual Off Back and Forth 72 79 Double Back and Forth 200 207 Left and Right Toggle 80 87 Double Al...

Страница 13: ...ance if you wanted to turn on heads 1 2 6 and 8 while keeping heads 3 4 5 and 7 off you would use Advanced Head Select mode Though this method may seem somewhat confusing or difficult to implement it...

Страница 14: ...age based DMX controller some effects will likely not work properly Creating a DMX Circuit Your X Laser product can be linked to other X Laser fixtures or other DMX compatible fixtures To create this...

Страница 15: ...your cables are connected to the appropriate ports before powering on your equipment This damage is obvious upon inspection and is absolutely not covered by warranty Once the Router detects a signal...

Страница 16: ...e connected everything as shown in the en closed diagram Faulty cable Ensure that you are using standard straight through CAT 5 cable in good condition with a run of less than 300 DMX issue Ensure tha...

Страница 17: ...a defect Technical Specifications This laser product is designated as Class IIIB during all procedures of operation maintenance and service and may only be sold rented to or used by organizations whi...

Страница 18: ...after August 1 2009 If you have purchased an older laser with several smaller labels rest assured that those will remain legally compli ant Safety Graphic Description LASER Light Avoid Exposure To Bea...

Отзывы: