X/Y Menu
Zoning your laser is one of the most important setup steps and this menu is essential to accurate and
safe zoning. While many may choose to do all their zoning from the Master fixture via DMX or Art-Net,
it’s still essential to learn this menu.
X Invert
Flips the projection along the X Axis, left to right
Y Invert
Flips the projection along the Y Axis, top to bottom
X/Y Swap
Switches the X and Y axis, this way a projector mounted at 90 degrees
can maintain the same orientation as a projector mounted
traditionally
X/Y Ext. Control
This setting controls the X/Y size and position controls from the DMX
or Art-Net Input. Available options are:
1.
Full
–
DMX/Art-Net control is enabled, and is not limited by
the minimum and maximum values set in the X/Y Limits
submenu
2.
Scale
–
DMX/Art-Net control is enabled, but the DMX values
are scaled to the range between the minimum and maximum
values set in the X/Y Limits submenu
3.
Limit
–
DMX/Art-Net control of scale and positions is enabled,
but the DMX values are not permitted to go beyond the limits
set in the X/Y Limits submenu
4.
Disable - DMX/Art-Net control of scale and position is
disabled, and the size and position values from the X/Y
submenu are used
X Scale
Sets the X Scale from 1-256, with 1 being the minimum and 256 being
the maximum. This scale setting is ignored when DMX/Art-Net control
is enabled and X/Y Ext. Control is set to Full. The default is 128
Y Scale
Sets the Y Scale from 1-256, with 1 being the minimum and 256 being
the maximum. This scale setting is ignored when DMX/Art-Net control
is enabled and X/Y Ext. Control is set to Full. The default is 128
Y Offset
Sets the Y Offset from -100 to 100. This scale setting is ignored when
DMX/Art-Net control is enabled and X/Y Ext. Control is set to Full. The
default is 0
X Offset
Sets the X Offset from -100 to 100. This scale setting is ignored when
DMX/Art-Net control is enabled and X/Y Ext. Control is set to Full. The
default is 0
X/Y Limits
Sets the limits for Scale and Offset when X/Y Ext. Control is set to Scale