23
Laser Status:
This indicates the status of the laser’s internal safety systems. Statuses in
clude:
Enabled
- The projector is capable of emitting laser when an appropriate control signal is sent
Turn Key
–
The key switch is in the disarmed position
Interlock Open
–
The system detects that the etherStop interface remote interlock loop is open
(no etherStop pendant or compatible terminator connected, key switch not in the enabled position, or
BIG RED BUTTON pressed)
Indicator Fail!
- The emission indicator on the laser has failed. Per IEC60825 the emission
indicator is failsafe, so emission is prohibited
Not Ready
–
The system is not ready to emit laser for some internal reason
Suspended
–
Emission has been suspended due to an internal laser fault or diagnostic state
Release Reset
- the reset signal must be released before the laser will respond to the reset
button being pressed
Press Reset
–
The projector is ready to emit, but has not had the etherStop reset triggered
Wait
–
The projector is in the Emission Delay state and will be ready to emit at the end of the
Emission Delay period (ten seconds on most systems)
Additional status screens showing the status of the available control interfaces are available using the
left
and right
arrow keys.
To access the Main Menu from the System Status screen, press the Menu button. From the main
menu, pressing the back key will return to the status screen.
System Menu
The system menu includes frequently changed settings such as:
Personality
The DMX personality of the system. Available options are:
1.
Master only
2.
1X Basic Builder
3.
2X Basic Builder
4.
3X Basic Builder
5.
4X Basic Builder
6.
1X Advanced Builder
7.
2X Advanced Builder
8.
3X Advanced Builder
9.
4X Advanced Builder
These personalities are explained in depth in the Fixture Profile section of this manual.
Содержание SkyWriter HPX M-5