9
byte of the IP address. When the Network Switch is in the OFF position the unit
will use an IP address of 2.x.x.x. When the switch is on it will use an address of
10.x.x.x per the Art-Net standard. You can override this address convention by
manually entering a full IP address. If you have already manually entered a full
static address then the Network switch has no effect until a factory reset is done.
10. Connect the Net-IT to your working network with Art-Net or E1.31 sources or
consoles. Any Art-Net source on the network will automatically find the Net-IT. If
you configured the Net-IT to DHCP then it will stop
11. Connect a DMX 5-pin cable to output A of the Net-IT and run to your fixtures.
12. Install the supplied Infogate software onto a PC or Mac connected to your
network and launch it. If the network is properly configured the Infogate GUI will
connect to the Net-IT box as indicated by a small green box on the top right
corner of the Infogate program window showing “ArtNet Gtway”, “ArtNet PS600”,
E131 Gtway”, or “E131 PS600”. Note that this text can be changed from the
Infogate software so if the Net-IT has been previously used it may show other
text.