13
changer does not fit the fixture, you may be able to replace it with the Wybron Universal
Mounting plate.
The mounting plate allows you to position the
color changer with the gelstring rolling either
horizontally or vertically. However, Coloram IT
operates most effectively with the fan, which is
located in the top of the center panel, blowing air
vertically (as hot air naturally rises).
2.
Attach the safety cable
A safety cable is attached to the color changer.
Run this cable around the pipe or truss from
which you hang the light fixture and clip it to
itself.
Figure 4
3.
Mount the power supply
The PS Power Supply is designed to be free standing, truss mounted, or rack mounted.
You decide which mounting method best suits your application.
The power supply comes with a mounting bracket which hooks over the pipe or truss of
your lighting rig and is then locked into place with a thumb screw. If you have selected
this mounting method, connect the safety cable by running it around the pipe or truss to
which the power supply is attached.
The power supply can also be mounted into a 19" rack using the optional PS Power
Supply rack mount kit. The rack mount kit will accommodate two PS Power Supplies side
by side.
4.
Connect the color changers to the power supply
Connect the color changers to the power supply using 4-pin Coloram IT cable.
Refer to the HEAD-FEET RESTRICTIONS section of this manual for details regarding
the length of cable runs.
5.
Connect the power supply to AC power
Plug the AC cord into a non-dimmed power circuit. The power supply automatically
accommodates 100 - 240 VAC (50/60 Hz).
Power at the PS Power Supply is indicated by a red LED indicator.
The connected color changers will automatically "calibrate" themselves to the gelstring
installed by doing the following actions: