WIRELESS CONNECTIVITY & SENSORS
User manual Thyone-I
9. UserSettings - Module configuration values
The settings described in this chapter are stored permanently in the module’s flash memory.
Depending on their corresponding permissions, their current values can be read out by the
command or modified by the
command. To do so the corresponding
settings index is used, which can be found in the primary table of each setting description.
The validity of the specified parameters is not verified. Incorrect values can
result in device malfunction.
After the modification of the non-volatile parameters, a reset will be necessary
for the changes to be applied.
When the configuration settings of the module are known in advance, an in-
dividualized firmware can be used to prevent in-field configuration. See chap-
ter
for more information regarding firmware individualization.
9.1. SERIAL_NUMBER: Read the serial number of the module
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of bytes
01
-
-
read
4
This setting contains the serial number of the module.
9.1.1. Example 1
Request the serial number of the module using
with settings index 01
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x01
0x12
Response
: Successfully read out the serial number, it is 0x6C000001
Start signal
Command | 0x40
Length
Status
Parameter
CS
0x02
0x50
0x05 0x00
0x00
0x01 0x00 0x00 0x6C
0x3A
Order code 2611011021000
84