Machine test - service program 07
International L – edition: 17.02.2006
23
7
Machine test - service program 07
You can start a test run to make sure your machine operates without a hitch.
!
Press button S until display shows
!
Press button 7:Leave the service program (
Press button 1:
Display shows program version.
First the IVC-program version (EPROM) is
displayed, e.g. 4.53 or higher, afterwards
date of release.
Then the display test starts in the four right-
hand digits. Press button C to return to test
program
Press button 2:
With a change giver or coin system each motor solenoid or motor is activated
once. To complete the test press key C.
Press button 4:
Cash flap opens once (machines with escrow unit only). Then press button C.
Press button 5:
Return flap opens once (machines with escrow unit only). Then press button C.
Press button 6:
Coins accepted now for some 5 seconds.
When inserting the coins, the coin channel
involved is displayed.
To complete the job press key C.
Press button 7:
Motor test
All available selections are operated once.
This test tries to run also all selections which
are not available like disconnected motors or
trays and disables them if noted. The same
applies after adding trays the relevant trays
will be enable. The compartment being
tested is shown in the display in the last two
digits.
NOTE:
If two motors operate in parallel mode they will be tested separatly. That
is no problem with empty spirals, but if these are filled with wide products
for double spirals it may cause a blockage.
If the motor test does not run the 'spiral single shut down' mode in service pro-
gram 15, button 9 may not be programmed,
Press key C to complete the job.
07 TEST PROGRAM
SELECTION:
01 =0453
SELECTION:
01 =1511
SELECTION:
06 = 06
SELECTION:
06 = 2
coin channel 2
SELECTION:
07 =7 10
SELECTION:
07 =7 89