background image

WUNDER SA.BI. SRL                                                                                                                       USER MANUAL 

 

RT10-15 REV. 00-305/05/2013                                                1                                                       

 

 
 
 
 

 

             

 

www.wunder.it

 

 

MDD HANGING SCALE 

  MOD. RT 

                                            

USER MANUAL  

 

 

 

 

      

  

    

   

 

 

Read this manual carefully before using the instrument 

 

 

 

 

2. 

GENERAL RULES…………………………………………………………………………………………………………………………………………. 

PAGE 2 

3. SAFETY…………………………………………………………………………………………………………………………………………………..... 

PAGE 

4. 

TECHNICAL SPECIFICATION…………………………………………………………………………………………………………………………… 

PAGE 3 

5. INDICATOR………………………………………………………………………………………………………………………………………………… 

PAGE 

6. 

INSTRUCTION FOR USE.………………………………………………………………………………………………………………………………… 

PAGE 4 

7. 

BATTERY INSTALLATION…………………………………………………………………………………………………………………………………. 

PAGE 7 

8. 

ERROR MESSAGE………..……………………………………………………………………………………………………………………………….. 

PAGE 8 

9. 

MAINTENANCE AND ASSISTANCE………………………………………………………………………………………………………………………. 

PAGE 8 

10. CONFORMITY………………………………………………………………………………………………………………………………………………. 

PAGE 

11. 

SCRAPPING AND WASTE DISPOSAL ………………………………………………………………………………………………………………….. 

PAGE 9 

12. WARRANTY………………………………………………………………………………………………………………………………………………….. 

PAGE 

10 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание RT 10

Страница 1: ... carefully before using the instrument 2 GENERAL RULES PAGE 2 3 SAFETY PAGE 3 4 TECHNICAL SPECIFICATION PAGE 3 5 INDICATOR PAGE 4 6 INSTRUCTION FOR USE PAGE 4 7 BATTERY INSTALLATION PAGE 7 8 ERROR MESSAGE PAGE 8 9 MAINTENANCE AND ASSISTANCE PAGE 8 10 CONFORMITY PAGE 9 11 SCRAPPING AND WASTE DISPOSAL PAGE 9 12 WARRANTY PAGE 10 ...

Страница 2: ...ES Carefully read this manual before using the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication Conventions The following symbols have b...

Страница 3: ...power supply provided by Wunder Before using it make sure that the local mains voltage is compatible with the voltage of the adapter shown on the identification plate Regularly check the integrity of the instrument s power cord and make sure it does not come in contact with hot appliances Make sure that the power cord does not create obstruction hazards Unplug the instrument before cleaning it Do ...

Страница 4: ...LD press HOLD for lock weight TARE press TARE weight of subject such as diaper or clothes put in the sling When the power is on the HOLD feature will automatically switch on and the arrow at Hold will flash When the weight is greater than 200g and is stable the arrow stops flashing and display locks Press HOLD to release 6 INSTRUCTION FOR USE DO NOT USE THIS DEVICE WITHOUT ANY HELP FROM MEDICAL PR...

Страница 5: ... 05 2013 5 CORRECT POSTURE DURING WEIGHT ATTENTION VISUAL INSPECTING HOOK AND SLING WITHOUT ANY BREAKAGE CORRECT POSTURE HOOK AND BABY BAG ATTENTION IT IS RECOMMENDED TO PLACE A CUSHION UNDER BABY SLING BEFORE WEIGHING TO MAKE BABY COMFORT AND SAFE ...

Страница 6: ... turn the scale on Smoothing out your sling Gently pose comfortable in the sling 4 5 6 Hanging S hook on the scale first Hook the sling and lift the baby gently Check the result while lifting the baby 7 8 If the result is flashing means the result is being locked Gently lay the baby down and check the result on scale ...

Страница 7: ...WUNDER SA BI SRL USER MANUAL RT10 15 REV 00 305 05 2013 7 7 BATTERY INSTALLATION ...

Страница 8: ...ting service2 wunder it or sales wunder it 1 Low battery indication This warning show that the voltage of battery is too low for operation please replace battery 2 Overload Zero counting value high Please remove subject on the scale and restart again if the problem still exists please contact your local WUNDER service partner for service 3 Zero counting value low Internal zero counting value is to...

Страница 9: ...pon purchase of a new equivalent appliance The user is responsible for bringing the appliance to an appropriate collection structure at the end of its life Appropriate separate collection and sending the appliance for recycling treatment and environmentally compatible waste disposal contributes to avoid possible negative effects on the environment and health and favours the recycling of the materi...

Страница 10: ...e caused by an insufficient or inadequate electrical system or alterations resulting from environmental climatic or other types of conditions damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel Interventions at home for convenience controls or presumed defects Routine maintenance and that which can be considered normal wear from use consumables s...