background image

1943-M032-O1 Rev B 

 Floor Hugger Series FHLT 

 
 
 
 
 

Floor Hugger 

Series FHLT 

Low Profile Electronic 

Lift-up Top Platform Scale 

Owner’s Manual 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 

1943-M032-O1 Rev B 

203 E. Daugherty, Webb City, MO 64870 USA 

 

02/15 

Ph: 417-673-4631 

 Fax: 417-673-2153 

Printed in USA 

 

www.cardinalscale.com 

 

Technical Support: Ph: 866-254-8261 

 [email protected] 

 

Summary of Contents for Floor Hugger FHLT Series

Page 1: ...Series FHLT Low Profile Electronic Lift up Top Platform Scale Owner s Manual 1943 M032 O1 Rev B 203 E Daugherty Webb City MO 64870 USA 02 15 Ph 417 673 4631 Fax 417 673 2153 Printed in USA www cardinalscale com Technical Support Ph 866 254 8261 tech cardet com ...

Page 2: ...1943 M032 O1 Rev B Floor Hugger Series FHLT 2 ...

Page 3: ...eproduction or use without express permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein DISCLAIMER While every precaution has been taken in the preparation of this book the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from...

Page 4: ......

Page 5: ...osal Scale should remain packed until you are ready to install it protecting it while being stored Remove shipping bands and packing material Make certain all packing material is removed Remove wooden box containing load cell cable from pallet Place on scale platform until further instructions are given BE CERTAIN scale location is level and free of debris Using the lifting eye bolt provided move ...

Page 6: ...me in contact with the ramp s as this can interfere with weighments taken Remove load cell cable from wooden box connect cable to weight indicating instrument following instructions provided in instrument manual Make certain cable is not placed near heating or cooling ducts relay panels ovens or other types of electrical equipment All cables should be routed out of the way of normal traffic and se...

Page 7: ...ted to digital display Please check the following before proceeding 1 Make certain proper installation procedures were followed 2 Is debris near or under scale deck such as packing material restricting proper scale operation Calibration procedures should be performed by a qualified scale technician or someone familiar with scale calibration procedures 3 Place test weight equal to ten percent of th...

Page 8: ... access cover 2 Refer to Figure No 2 for load cell location reference 3 Turn trim potentiometer for the load cell needing re calibration clockwise 25 turns the end of the potentiometer adjustment 4 Place a test weight on each corner one at a time and record the displayed weight for each corner 5 Place test weight on the corner with the highest reading and adjust the appropriate trim potentiometer ...

Page 9: ... on corner no 1 and adjust no 1 trim potentiometer to reduce displayed weight to the lowest corner reading No 2 in example 3 Repeat step 2 with corners no 3 and 4 until all corners are in agreement 4 Calibrate weight indicator following instructions provided in its manual TROUBLE SHOOTING GUIDE If difficulty is encountered with the operation of the scale a visual check of the scale platform should...

Page 10: ...1943 M032 O1 Rev B Floor Hugger Series FHLT 6 INTERCONNECTION DIAGRAM FIGURE No 3 ...

Page 11: ...ised position release the prop angle from its loose position and let it rotate downward to engage gas spring Lower the weighbridge and locate the prop angle on gas spring 3 To lower the weighbridge top raise to allow the prop angle to become free rotate and return it to its loose position Push down on weighbridge from point 2 CAUTION Do not let body parts come between weighbridge and base as you a...

Page 12: ...1943 M032 O1 Rev B Floor Hugger Series FHLT 8 PARTS IDENTIFICATION FHLT 544S ...

Page 13: ... 7 4 1932 B041 0A FOOT ASSY 2 DIA 8 2 6031 0191 GAS SPRING 9 2 6021 1242 SCW SHOULDER 3 8 DIA x 2 1 2 S S 10 5 6021 1234 SCW SHOULDER 3 8 DIA x 1 1 2 S S 11 7 6013 0058 NUT ELAS STOP 5 16 18 S S 12 1 1943 B078 08 PROP ANGLE 13 6 6024 1061 WASHER FLAT 3 8 S S 14 2 6020 0011 SPRING PIN 1 8 X 3 4 LG S S 15 2 6022 0032 SPRING COMP S S 16 4 418R1047 EYE BOLT USED FOR TRANSPORTING 17 2 1943 B065 0A PIN ...

Page 14: ...1943 M032 O1 Rev B Floor Hugger Series FHLT 10 PARTS IDENTIFICATION CONT REMOTE TRIM BOX ...

Page 15: ...1 3502 B403 08 GASKET 4 1 3502 C205 0A PC BD ASSEMBLY 6 2 6021 0661 SCW PHMS S S 6 32 x 1 4 7 4 6610 1150 GLAND CONNECTOR SMALL 8 1 6610 2248 GLAND CONNECTOR LARGE 9 6 6021 1013 SCW RHMS S S 10 32 x 3 8 10 2 6021 1108 SCW FIL HMS S S 10 32 x 3 8 11 1 6560 0064 DESICCANT PACK 12 0 3502 A395 PS PRODUCTION SPEC 13 3 4 6710 1017 ADHESIVE TAPE 1 PIECE CUT 3 4 LONG 15 2 6540 1104 HOLE PLUG ...

Page 16: ...n purchased with Guardian Vehicle Scale LIFE YES YES YES YES 90 DAYS 1 5 6 8 A B C D HYDRAULIC LOAD CELLS When purchased separately 10 YEARS YES YES YES YES NO 1 5 6 8 9 A B C D VEHICLE SCALE Deck and Below Excl PSC Series 5 YEARS YES YES YES YES 90 DAYS 1 2 3 5 6 A B C D E PSC and LSC SCALE STRUCTURES Deck and Below 3 YEARS YES YES YES YES 90 DAYS 1 2 3 5 6 11 A B C D GUARDIAN FLOOR SCALES 10 YEA...

Page 17: ... any item that has been damaged due to unusual wear abuse improper line voltage overloading theft fire water prolonged storage or exposure while in purchaser s possession or acts of God unless otherwise stated herein This warranty does not apply to peripheral equipment not manufactured by Cardinal This equipment will normally be covered by the equipment manufacturer s warranty This warranty sets fo...

Page 18: ...1943 M032 O1 Rev B Floor Hugger Series FHLT 12 ...