4.3.2. Default Flow Control Format (Sw3)
SetUp Switch three selects the default flow control (handshaking) format for the serial Modem
Port. The Modem Port flow control format can also be selected via the Modem Parameters
Menu. If the unit is reinitialized, the flow control format will return to the setting specified b y
SetUp Switch three.
Default Flow Control Format
Sw3
None *
Down
RTS/CTS (Hardware)
Up
* = Factory Setting
4.3.3. Default Bits and Parity (Sw4)
SetUp Switch four selects the default bits and parity setting for both the internal modem and
the serial Modem Port. The bits and parity can also be selected via the Modem Parameters
Menu (/M). If the unit is reinitialized, bits and parity will return to the setting specified by
SetUp Switch four.
Default Bits and Parity
Sw4
8 Bits, No Parity, 1 Stop Bit *
Down
7 Bits, Even Parity, 1 Stop Bit
Up
* = Factory Setting
4.3.4. Default Rings to Answer (Sw5)
SetUp Switch five selects the default “Rings to Answer” setting. The Rings to Answer setting
can also be defined via the Modem Parameters menu (/M). If the SRM-100 is reinitialized, the
Rings to Answer feature will return to the setting selected by SetUp Switch five.
Default Rings to Answer
Sw5
One *
Down
Eight
Up
* = Factory Setting
4-3
SRM-100 - Secure Rack Modem, User's Guide
Hardware Installation