4-2

Hardware Installation

• 

Other NPS Series Units:

  These units include pre-installed cable keepers.  When 

attaching the power supply cables to the unit, first swing the cable keepers out 
of the way, then plug the power cables securely into the power inputs.  When the 
cables are in place, snap the cable keepers over each plug to secure the cables to 
the unit.

4.1.2.  Connect the NPS to Your Power Supply

Refer to the cautions listed below and at the beginning of this User's Guide, and 
the information on the instrument name plate, and then connect the NPS unit to an 
appropriate power supply.

Note:  

Some NPS units are shipped with one or two detachable 125 VAC, 

15 Amp "Starter" Cables.  These cable(s) will allow you to connect a 120 VAC 
NPS unit to power for bench testing and initial start up and are adequate for 
applications that only require 15 Amps.  For higher amp power switching 
applications, please refer to the WTI Power Cable Guide (which can be found at 
https://www.wti.com/guides/powercables_refguide.pdf
.)

4.2.  Connection to Switched Outlets

Connect the power cord from your switched device to one of the AC Outlets on the NPS 
unit.  Note that when power is applied to the NPS, the AC Outlets will be switched “ON” 
by default.  Note that some NPS models include two separate power branches, while 
others feature only one power branch.

4.3.  Serial SetUp Port Connection

The NPS SetUp Port is a female, RJ45 RS232 connector, wired in a DCE configuration.  
In the default state, the Setup port is configured for 9600 bps, no parity, 8 data bits, 1 
stop bit.  The Setup Port can be connected to either an external modem or a local PC, 
but not both items at the same time.  Appendix B describes the Setup Port interface.

4.3.1.  Connecting a Local PC

Use the DX9F-WTI Adapter supplied with the unit to connect your PC COM port to the 
NPS Setup Port.  Make certain that the Serial Port Mode is set to “Normal” as described 
in the WTI Firmware Guide.

4.3.2.  Connecting an External Modem

When connecting directly to an external modem, use the optional DX9M-RJ-KIT (not 
included) to connect your external modem to the NPS Setup Port.  Make certain that the 
modem is initialized at the same default parameters as the NPS Setup Port and that the 
NPS Serial Port Mode is set to “Modem” as described in the WTI Firmware Guide.

Содержание NPS-16HD Series

Страница 1: ...WTI Part No 14531 Rev A NPS Series NetworkPowerSwitches HorizontalMount Products Covered NPS 4HS15 Series NPS 8HS Series NPS 8HD Series NPS H20 ATS Series NPS 16HD Series Hardware Guide...

Страница 2: ...current protection and supply wiring Grounding Reliable earthing of this equipment must be maintained Particular attention should be given to supply connections when connecting to power strips rather...

Страница 3: ...ice or remove the unit 15 Amp Starter Cable s Depending on your specific model some NPS Series units may be shipped with either one or two 125 VAC 15 Amp Starter Cables These Starter Cables will allow...

Страница 4: ...two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Changes or mod...

Страница 5: ...Started 3 1 3 1 Apply Power to the NPS 3 1 3 2 Connect Your Computer to the NPS 3 1 3 3 Communicating with the NPS 3 2 3 4 Controlling Power Outlets 3 2 4 Hardware Installation 4 1 4 1 Connecting the...

Страница 6: ...rk equipment sites and off site facilities by providing secure remote access to power switching and reboot functions at the remote network equipment site Note For instructions regarding configuration...

Страница 7: ...terminal or external modem as described in Section 4 3 For a description of the Setup Port interface please refer to Appendix B 3 ON Indicator An LED that lights when power is applied to the NPS 4 RDY...

Страница 8: ...es power to NPS control functions and outlets Also includes cable keeper not shown NPS 4HS15 1 Units One IEC 60320 C14 inlet for 100 120V power NPS 4HS15 2 Units One IEC 60320 C14 inlet for 100 240V p...

Страница 9: ...2 ON Indicator An LED that lights when power is applied to the NPS 3 RDY Indicator Ready Flashes if unit is ready to receive commands 4 Default Button Toggles outlets On Off or resets unit to factory...

Страница 10: ...hed Outlets AC Outlets that can be switched On Off rebooted or set to default state in response to user commands NPS 8HS20 1 Units Eight NEMA 5 15R Outlets NPS 8HS20 2 Units Eight IEC 60320 C13 Outlet...

Страница 11: ...D that lights when power is applied to the NPS 3 RDY Indicator Ready Flashes if unit is ready to receive commands 4 Default Button Toggles outlets On Off or resets unit to factory default parameters a...

Страница 12: ...unts Mounting Hardware for Cable Retainer Bracket Switched Power Outlets Eight switched power outlets four switched outlets per branch that draw power from the corresponding branch power inlet 4 Branc...

Страница 13: ...re information on Network Port configuration please refer to the WTI Firmware Guide 3 ON Indicator An LED that lights when power is applied to the NPS 4 RDY Indicator Ready Flashes if unit is ready to...

Страница 14: ...TS Units IEC 60320 C20 inlet for 100 120V power NPS 8H20 2 ATS Units IEC 60320 C20 inlet for 200 240V power 2 Secondary Power Inlet NPS 8H20 1 ATS Units IEC 60320 C20 inlet for 100 120V power NPS 8H20...

Страница 15: ...ault parameters as described in Section 2 11 5 Reset Button Reboots and or resets the NPS to factory defaults as described in Section 2 11 6 Output Status Indicators LEDs light when corresponding outl...

Страница 16: ...for 200 240V power 2 Branch B Power Inlet Supplies power to outlets B1 through B8 NPS 16HD20 1 Units IEC 60320 C20 inlet for 100 120V power NPS 26HD20 2 Units IEC 60320 C20 inlet for 100 240V power N...

Страница 17: ...ranch For information on Alarm Configuration please refer to the WTI Firmware Guide 7 Network Port An RJ45 Ethernet port for connection to your 10 100 1000Base T TCP IP network Note that the Network P...

Страница 18: ...seconds and then release it b The NPS will reboot it s operating system all plugs will be left in their current On Off state 2 Set Parameters to Factory Defaults a Simultaneously press both the Defaul...

Страница 19: ...wer is applied to the NPS the ON LED on the instrument front panel should light and the RDY LED should begin to flash within 90 seconds indicating that the unit is ready to receive commands Note To de...

Страница 20: ...Status Screen Text Interface 3 4 Controlling Power Outlets If you wish to verify that the NPS is operating properly before deploying the unit in a working network environment proceed as follows to co...

Страница 21: ...designed to prevent the power supply cables from being accidentally disconnected from the unit NPS 8HD Series Units Cable keepers must be installed by the user 1 First make certain that both of the NP...

Страница 22: ...onnect the power cord from your switched device to one of the AC Outlets on the NPS unit Note that when power is applied to the NPS the AC Outlets will be switched ON by default Note that some NPS mod...

Страница 23: ...determine if the device is 1000Base T 100Base T or 10Base T and then configure the network interface accordingly If your router switch does not autosense the NPS will auto negotiate speed and duplex m...

Страница 24: ...ht 1 75 4 5 cm One Rack U NPS 8HS Series NPS 8HD Series NPS 8H20 ATS Series Width 19 48 3 cm Including Rack Brackets Depth 8 7 22 1 cm Height 1 75 4 5 cm One Rack U NPS 16HD Series Width 19 48 3 cm In...

Страница 25: ...r Modem Mode the DTR output at either port reflects the DCD input at the other end b If neither port is set for Modem Mode DTR output is held high active 2 When not connected a If the port is set for...

Страница 26: ...e of the unit its serial number and a description of its symptoms If the unit should need to be returned for factory repair it must be accompanied by a Return Authorization number from Customer Servic...

Страница 27: ...mation and descriptions contained herein are the property of Western Telematic Inc Such information and descriptions may not be copied disseminated or distributed without the express written consent o...

Отзывы: