Rev 5.0/2-21
MRTA8-DC3: #35121AUS
27
T
O
R
ELEASE
THE
P
ADS
FROM
THE
L
OAD
1A
Make sure load is at rest and fully supported before
releasing vacuum pads.
1) Hold the “function” button (
— fig. 1A) and the “release”
button (
— fig. 1A). If the vacuum seal does not break,
follow the directions on the LCD screen.
1B
Note: The strobe light (fig. 1B) flashes while the “function” or
“release” button is held, to show the operator that signals
are being transmitted and to warn others that the operator
may be releasing the load.
2)
Do not move lifter until pads
release completely, because
such movement could result in load
damage or personal injury.
Continue to hold the “function” and “release”
buttons until the vacuum pads release the load
completely. Otherwise, the vacuum lifter will
automatically revert to “attach” mode.
1
After the load is successfully released, the lifter activates the “Power Save” mode
automatically.
3) Before you lift another load, perform the Every-Lift Inspection (see
).
1..... A “Timed Release” function can be used to help separate the lifter from the load: Hold the “function” and “release” buttons until a yellow arrow
appears on the LCD screen. Then tap the “function” button 2 or more times. This prolongs the release mode for 5 seconds per each additional
tap.
OPERATION
Содержание QUADRA-TILT MRTA810CDC3O
Страница 2: ...MRTA8 DC3 35121AUS Rev 5 0 2 21 2...
Страница 6: ...MRTA8 DC3 35121AUS Rev 5 0 2 21 4 Note A standard MRTA811LDC3 is shown SPECIFICATIONS...
Страница 11: ...Rev 5 0 2 21 MRTA8 DC3 35121AUS 9 TO CHANGE THE PAD FRAME CONFIGURATION ASSEMBLY...
Страница 47: ...Rev 5 0 2 21 MRTA8 DC3 35121AUS 49...
Страница 48: ...MRTA8 DC3 35121AUS Rev 5 0 2 21 50...