background image

Rev 4.0/8-17 

N4950/N10TAIR: #35105 

SPECIFICATIONS 

 

Description: 

Designed for use with a compressed air supply, these N-Series hand cups 

employ vacuum for attaching to loads, which are manually lifted and 

carried, offering a wide range of handling options. 

Model Number: 

N4950AIR 

N10TAIR 

Vacuum Pad / Pad Spread: 

8" [20 cm] nominal diameter 

(Model G0695) 

10" [25 cm] nominal diameter 

(Model VPFS10T

1

 

(one of standard rubber with #60 filter screen) 

Maximum Load Capacity: 

125 lbs [57 kg] 

150 lbs [68 kg] 

 

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

2

Hand Cup Weight: 

3 lbs [1.36 kg] 

5.25 lbs [2.38 kg] 

Power Source: 

Compressed air, 70-80 psi [483-552 kPa] line pressure, 2 SCFM [57 

liters/minute] @ 75 psi [517 kPa] 

Vacuum Pump: 

Venturi type, 1 SCFM [28 liters/minute] nominal vacuum flow @ 75 psi 

[517 kPa] 

Vacuum Indicator: 

When hidden, red line on plunger indicates current vacuum level is 

adequate for lifting a load. 

Operating Elevation: 

Maximum = 9000 feet [2743 meters] 

Operating Temperatures: 

10° to 120° F [-12° to 49° C] 

Service Life: 

This hand cup is designed to have a service life of at least 20,000 lifting 
cycles, when used and maintained as intended.  Vacuum pads and other 

wear-out items are excluded (see MAINTENANCE and REPLACEMENT 

PARTS LIST for more information).  For the D

ISPOSAL OF THE 

H

AND 

C

UP

 after 

its service life, see INTENDED USE. 

 

                                        

1

  The replaceable sealing ring on this vacuum pad is used for applications on rough or textured surfaces (see REPLACEMENT 

PARTS LIST). 

2

  Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM 

P

AD 

M

AINTENANCE

: Friction Coefficient for 

additional information. 

Содержание N10TAIR

Страница 1: ...__________ please see serial label and record number here HAND HELD VACUUM CUP AIR POWERED READ ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS HAND CUP DESIGNED FOR THE MATERIALS HANDLING PROFESS...

Страница 2: ......

Страница 3: ...he Red Line Vacuum Indicator 9 Lifting the Load 9 Monitoring the Red Line Vacuum Indicator 9 In Case of Power Failure 9 TO RELEASE THE HAND CUP FROM THE LOAD 10 AFTER USING THE HAND CUP 10 MAINTENANCE...

Страница 4: ...Vacuum Pump Venturi type 1 SCFM 28 liters minute nominal vacuum flow 75 psi 517 kPa Vacuum Indicator When hidden red line on plunger indicates current vacuum level is adequate for lifting a load Oper...

Страница 5: ...s of the load and the vacuum pad are clean prior to attaching the pad see MAINTENANCE VACUUM PAD MAINTENANCE Never exceed the Maximum Load Capacity or attempt to lift loads the hand cup is not designe...

Страница 6: ...ing instructions for assembling operating or maintaining the hand held vacuum cup are underlined on their first appearance in each section Standard N4950AIR shown 1 VACUUM PAD 5 VACUUM RELEASE BUTTON...

Страница 7: ...t it does not become tangled kinked pinched or cut while operating the hand cup or production machinery Any damage or obstruction in the air line would result in an immediate load release and possible...

Страница 8: ...ion cannot be avoided Wood s Powr Grip does offer a heat resistant rubber compound and other solutions which may enable you to lift loads with higher surface temperatures Contact Wood s Powr Grip or a...

Страница 9: ...s indicated in SPECIFICATIONS Using the hand cup in wet environments may require the operator to take special precautions Moisture on contact surfaces of the load or the vacuum pad diminishes the hand...

Страница 10: ...sary for each type of load material TO ATTACH THE HAND CUP TO A LOAD WARNING Never interrupt vacuum flow while operating hand cup keep pump running throughout lift The hand cup is designed for the vac...

Страница 11: ...gnal the reduction in vacuum to the operator WARNING Monitor red line indicator throughout entire lift Check the red line indicator frequently to make sure the vacuum pad is attached securely If the r...

Страница 12: ...engages completely from the load Then move the hand cup away Continue to hold the release button until the pad is well away from the load otherwise the hand cup would reattach itself to the load AFTER...

Страница 13: ...system including fittings and hoses for visual damage Check for unusual vibrations or noises while operating the hand cup If any deficiency is detected during the inspection correct it before using th...

Страница 14: ...tion coefficient of 1 However a vacuum pad s ability to maintain this friction coefficient is reduced by factors such as contamination wear age and exposure to sunlight as well as the condition of the...

Страница 15: ...riction Coefficient preceding The use of any unauthorized cleaning agent is prohibited because it could damage the pad and or create a hazard to the operator or others WARNING Never use solvents gasol...

Страница 16: ...g groove 3 Push the sealing ring insert into the mounting groove beginning in 4 locations as shown 4 Push gently and firmly on the outside edge of the ring insert until its base flat side fits flush a...

Страница 17: ...Model VIFS10T3 Heat Resistant Rubber for VPFS10T pad 1 49672FT Vacuum Pad Model VPFS10T 10 25 cm Diameter w Replaceable Sealing Ring 1 49486T Vacuum Pad Model G0695 8 20 cm Diameter 1 29353 Pad Cover...

Страница 18: ...use Repairs are required due to abnormal wear and tear The product has been damaged misused or neglected If a problem is not covered under warranty Powr Grip will notify the customer of costs prior t...

Отзывы: