Rev 4.0/8-17
11
N4950/N10TAIR: #35105
MAINTENANCE
I
NSPECTION
S
CHEDULE
Perform inspections routinely, according to the following frequency schedule:
Every-Lift Inspection
• Examine the vacuum pad and load surface for contamination or debris (see V
ACUUM
P
AD
M
AINTENANCE
to follow).
• Examine the vacuum pad, red-line vacuum indicator and other OPERATING FEATURES for
visual damage (see V
ACUUM
P
AD
M
AINTENANCE
to follow).
If any deficiency is detected during the inspection, correct it before using the hand cup and
perform the Frequent Inspection to follow.
Frequent Inspection
(
following every 20-40 hours’ use; or whenever hand cup is out of service for 1 month or more)
• Examine the hand cup’s structure for visual damage.
• Examine the air supply system (including fittings and hoses) for visual damage.
• Check for unusual vibrations or noises while operating the hand cup.
If any deficiency is detected during the inspection, correct it before using the hand cup and
perform the Periodic Inspection to follow.
Periodic Inspection
(
following every 250-500 hours’ use; or whenever hand cup is out of service for 1 year or more)
• Examine the entire hand cup for external evidence of looseness, excessive wear, deformation,
cracks, excessive corrosion, dents to structural or functional components, cuts, or any
deficiency which might constitute a hazard.
• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, return the hand cup to Wood’s Powr-Grip or
an authorized dealer for repair (see LIMITED WARRANTY).
Infrequent Use
If a hand cup is used less than 1 day in a 2-week period, perform the Periodic Inspection
each
time before using the hand cup.