Rev 10.3/10-16
10
MTCL8FS10TDC: #35079
To Install/Remove Pad Frame Extensions
1) Insert the end of a pad frame extension in one socket on the main pad frame, so that the
holes align for the cotterless hitch pin.
2) Secure the pad frame extension in the pad frame by pushing a cotterless hitch pin through
the holes until the retaining ball emerges on the far side of the pad frame socket.
3) Use the quick connectors to connect the vacuum hoses from the pad frame extensions to the
main pad frame as directed in the discussion to follow.
3) Repeat steps 1-3 to install the other pad frame extensions as required for the pad frame
configuration desired.
4) To remove the pad frame extensions, reverse this procedure. Store pad frame extensions in
a clean, dry location to protect them from environmental exposure.
To Install/Remove, Rotate and Position Pad Mounts
1) Position a pad mount on one arm of the pad frame. Note that each pad mount can also be
rotated 180° to allow for the best hose routing.
2) Align the holes for the cotterless hitch pin in the pad mount with the corresponding holes in
the pad frame.
3) Use the quick connector to connect the vacuum hose from the vacuum pad to the appropriate
circuit of the vacuum system as directed in the discussion to follow.
4) Repeat steps 1-3 to install and position each vacuum pad as required for the pad frame
configuration desired.
5) To remove the pad mounts, reverse this procedure. Store pad mounts in a clean, dry location
to protect them from environmental exposure.
To Connect/Disconnect Vacuum Hoses
The vacuum hose for each vacuum pad is connected to or
disconnected from the vacuum system by means of a quick
connector. To connect the vacuum hose, push the male and
female ends of the connector together until they lock. To
disconnect the vacuum hose, move the release ring on the
female end until the connector separates.
Note: For proper function of the dual vacuum system, make sure
that vacuum pads are connected to alternating circuits of the
vacuum system (red or green).
Note: Whenever a quick connector is disconnected, the corresponding vacuum pad does not
contribute to the load capacity, whether or not the pad is mounted on the pad frame.
QUICK CONNECTOR
1) FEMALE END
2) MALE END
Содержание MTCL8FS10TDC
Страница 2: ...View Quick Start Guide...
Страница 40: ...Rev 10 3 10 16 38 MTCL8FS10TDC 35079...
Страница 41: ...Rev 10 3 10 16 39 MTCL8FS10TDC 35079...
Страница 42: ...Rev 10 3 10 16 40 MTCL8FS10TDC 35079...
Страница 43: ...Rev 10 3 10 16 41 MTCL8FS10TDC 35079...
Страница 44: ...Rev 10 3 10 16 42 MTCL8FS10TDC 35079...
Страница 45: ...Rev 10 3 10 16 43 MTCL8FS10TDC 35079...
Страница 46: ...Rev 10 3 10 16 44 MTCL8FS10TDC 35079...