To use the optional Remote Control System, press the “attach”
button (
— fig. 1D) on the radio transmitter.
The vacuum pump will run until the vacuum pads seal completely. If the lifter takes too long to
attach, the notification buzzer chirps and the LCD screen displays “Vacuum not increasing
normally”, along with a diagnostic code (see
). In this case, press
the lifter firmly against the load to help the pads begin to seal.
1
Reading the Vacuum Gauges
The 2 vacuum gauges of the dual vacuum system show the current vacuum level in positive
inches of Hg and negative kPa:
•
1A
1B
Green
range (> 16" Hg [-54
kPa]): Vacuum level is sufficient
to lift the maximum load weight
(fig. 1A).
• Red
range (< 16" Hg [-54 kPa]):
Vacuum level is
not
sufficient to
lift the maximum load weight
(fig. 1B).
2
If it takes more than 5 seconds for the
vacuum level to reach 5" Hg [-17 kPa]
on either vacuum gauge, press on any
vacuum pad that has not yet sealed.
Once the pads have sealed, the lifter should be able to maintain sufficient vacuum for lifting,
except when used above the maximum Operating Elevation.
3
If it does not, perform the
1..... Although a vacuum pad may become distorted during shipping or storage, this condition should correct itself with continued use.
2..... The gauge face colors do not correspond with the circuit colors.
3..... If the lifter is used above the maximum Operating Elevation (see “SPECIFICATIONS”), it may not be able to maintain sufficient vacuum for lifting.
Contact WPG for more information.
OPERATION