9
Operational Modes
Normal Operation
When you scan, you will get one high pitched beep when you get a successful decode. The data is then
transmitted to the USB Base Station receiver (as it is being transmitted, the LED turns blue). When the Laser
receives the acknowledgement from the Base Station that the data has been received, the RF Laser emits a
lower pitched beep and turns on a green LED.
If the transmitted data fails to be acknowledged,
1)
Further scanning is prohibited. You can't scan again until the data reaches the base or you clear the
scanner.
2)
The laser will retransmit three times, (the yellow LED will indicate retransmissions) each time the
trigger is pulled.
3)
If the transmission fails three times, the RF Laser will emit a distinct 8 beep pattern and turn off.
The scanned data is saved in the memory of the RF Laser until it is successfully transmitted to the
Base or deleted by the user. Check out the Base Station or move closer.
4)
You can clear the pending data transmission by holding down the trigger on the RF Laser Scanner
for 10 seconds. After 10 seconds, the data from the last scan will be deleted and the RF Laser
Scanner will be able to scan bar codes again.
Power Modes
The 1D RF Laser goes into a low-power standby mode when the trigger is released. In this mode, all the
components of the scanner are powered but in standby to provide a snappy response when the trigger is pulled.
A fully charged battery will last approximately three weeks in this mode if it is not charged sooner. If you
wish to completely power-down the 1D RF Laser then scan the bar code below. Any trigger pull after
scanning the below bar code will wake up the scanner and put it into standby mode. When waking up from
the power down state, there is a delay of about 2 seconds for RF transmission. Only the first scan is delayed.
*/$E/*
The 2D RF Laser will automatically power down after sitting idle for 15 minutes. Any trigger pull will wake
up the scanner and put it into standby mode. When waking up from the power down state, there is a delay of
about 2 seconds for scanning and about 2 seconds for RF transmission. Only the first scan is delayed.
Power-down does not affect pairing or stored setup parameters.