2. safetY precautIons

 Do not operate the generator near gasoline or gaseous fuel because of the potential 

danger of explosion or fire.

 Do not fill the fuel tank with fuel while the engine is running. Do not smoke 

or use a naked flame near the fuel tank. Be careful not to spill fuel during 

refueling. If fuel is spilt, wipe it off and let dry before starting the engine.

 Do not place inflammable near the generator. Be careful not to place fuel, matches, gunpowder, 

oily cloths, straw, trash, or any other in flammables near the generator.

 Do not operate the generator inside a room, cave, tunnel, or other insufficiently ventilated area. 

Always  operate  it  in  a  well-ventilated  area,  otherwise  the  engine  may 

become  overheated,  and  the  poisonous  carbon  monoxide  gas  contained 

in  the  exhaust  gases  will  endanger  human  lives.  Keep  the  generator  at 

least  1  meter  (3  feet)  away  from  any  structure  or  building  during  use.  If 

the generator must be used indoors, the area must be well-ventilated and 

extreme caution must be taken regarding the discharge of exhaust gases. Failure to follow the 

correct procedures can be fatal.

 Do not enclose the generator nor cover it with a box. The generator has a built-in forced air cooling 

system, and may become overheated if it is enclosed. If generator has been covered to protect it 

from the weather during non use, be sure to remove it and keep it well away from the area during 

generator use.

 Operate the generator on a level surface. It is not necessary to prepare a special foundation for 

the generator. However, the generator will vibrate on an irregular surface, so choose a level place 

without surface irregularities. If the generator is tilted or moved during operation, fuel may spill 

and/ or the generator may tip over, causing a hazardous situation. Proper lubrication cannot be 

expected if the generator is operated on a steep incline or slope. In such a case, piston seizure 

may occur even if the oil level is above the minimum level.

 Pay attention to the wiring or extension cords from the generator to the connected 

device. If the wire is under the generator or in contact with a vibrating part, it may 

break  and  possibly  cause  a  fire,  generator  burnout,  or  electric  shock  hazard. 

Replace damaged or worn cords immediately.

 Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suffer 

severe electric shock if the generator is wet due to rain or snow.

 If the generator is wet, wipe and dry it before starting. Do not pour water directly over 

the generator, never wash it with water.

Содержание Robin Subaru ARC 160 EX

Страница 1: ...Instructions for use WELDERS GB MODELS Mixte 4500 3 2 Ex Mixte 5100 4 Ex Mixte 7000 4 Ex arC 160 ex arC 220 ex MU_02GE_MIXTE_EX_ARC_EX_GB...

Страница 2: ...ords Indicates an impending dangerous situation If this one is not prevented it can cause death or severe injuries for the user Indicates a strong possibility of severe personal injury loss of life an...

Страница 3: ...tions Page 8 4 pre operation check Page 9 5 operating ProcedureS Page 12 6 stopping the generator Page 16 7 oil sensor Page 16 8 wattage information Page 17 9 maintenance schedule Page 18 10 hoW to ma...

Страница 4: ...products and this instruction manual Read the operator s instruction manual Stay clear of the hot surface Exhaust gas is poisonous Do not operate in an unventilated room Stop the engine before refueli...

Страница 5: ...e polarity U r Rated voltage V Minus negative polarity T max Maximum ambient tempera ture C STOP position of a bistable push control COS Rated power factor ON position of a bistable push control I r R...

Страница 6: ...rator has a built in forced air cooling system and may become overheated if it is enclosed If generator has been covered to protect it from the weather during non use be sure to remove it and keep it...

Страница 7: ...y hot during and for some time after operation Keep combustible materials well away from generator area Be very careful not to touch any parts of the hot engine especially the muffler area or serious...

Страница 8: ...2 1 1 Three socket 400V 3P T N 16A 1 1 Protection Sockets Protected With a Circuit Breaker ENGINE Engine Model EX 27 EX 35 EX 40 EX 27 EX 40 Engine Type 4 Stroke Gasoline OHC Cooling System Air Coole...

Страница 9: ...ot screw in the oil filler cap when checking oil level Oil Capacity Upper Level MIXTE 4500 3 2 EX 1 0 L MIXTE 5100 4 EX 1 2 L MIXTE 7000 4 EX 1 2 L ARC 160 EX 1 0 L ARC 220 EX 1 2 L Change oil if cont...

Страница 10: ...city see page 8 Fuel Filter Screen Tank Cap Make sure you review each warning in order to prevent fire hazard Do not refill tank while engine is running or hot Close fuel cock before refueling with fu...

Страница 11: ...ailable connect the grounding lug of the generator to the grounding terminal of the using electric tool or appliance Earth Terminal 4 5 ELECTRIC STARTER OPTIONAL The battery is delivered dry but loade...

Страница 12: ...ually to OPEN position Recoil starter model Pull the starter handle slowly until resistance is felt This is the compression point Return the handle to its original position and then pull swiftly If th...

Страница 13: ...d Do not let the electrical running for more than 5 seconds even if the engine is not working I the engine doesn t start wait for roughly 10 secondw before starting again Never turn the switch key to...

Страница 14: ...s not exceed the rated output of the generator Do not put foreign objects into the plug receptacle NOTE When the circuit breaker or no fuse breaker turns off during operation the generator is overload...

Страница 15: ...spe cifications of current for each generator 5 4 FRONT WELDING PANEL ARC EX 1 Function Range of current selector graded in Amperes 2 Precise current selector graded in Amperes 3 Quick plug of weldin...

Страница 16: ...after a necessary cooling time see the information on the plate If during the work with some high current the thermal breaker is on you have to wait few minutes before resetting it 6 stopping the gen...

Страница 17: ...motor the appliance will require only 30 to 50 of the wattage to continue running Most electrical tools require 1 2 to 3 times their wattage for running under load during use For example a 5 000 watt...

Страница 18: ...1 5V 2 5V 4V 5V 6 5V 7 5V 3 5 10 8 35 70 0 32 0 332 1V 2V 2 5V 3 5V 4V 5V 9 maintenance schedule Daily 8 h Check all components according to PRE OPERATING CHECKS Check and refill gasoline and engine o...

Страница 19: ...change Change engine oil every 100 hours For new engine change oil after 20 hours 1 Drain oil by removing the drain plug and the oil filler cap while the engine is warm 2 Reinstall the drain plug and...

Страница 20: ...element set every 200 hours Dual Element Type Air Filter Covercle Air Filter Frame Urethane Foam Paper Element 2 Clean and replace air cleaner elements more often when operating in dusty environments...

Страница 21: ...Gap 0 6 to 0 7 mm SPARK PLUG MIXTE 4500 3 2 EX NGK BR 6HS MIXTE 5100 4 0 EX MIXTE 7000 4 0 EX ARC 160 EX ARC 220 EX 10 4 CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strai...

Страница 22: ...ly deteriorate making engine starting difficult Remove the carburetor float chamber and also drain the carburetor Change engine oil Check for loose bolts and screws tighten them if necessary Clean gen...

Страница 23: ...g cap If loose push spark plug cap back into place Check spark plug for contamination Remove spark plug and clean electrode 12 2 When no electricity is generated at receptacle Check to make sure no fu...

Страница 24: ...607 Marne la Vall e Cedex 3 FRANCE Commercial and Spare Parts Service TEL 33 0 1 64 76 29 60 FAX 33 0 1 64 76 29 99 After Sales Service TEL 33 0 1 64 76 29 80 FAX 33 0 1 64 76 29 88 Standard TEL 33 0...

Отзывы: