13. TROUBLESHOOTING
If, in spite of several attempts, the generator engine refuses to start or if the exit electricity is not
available, the board below must be consulted. If the generator does not still start or if the electricity is
not generated, get in touch with Worms
Entreprises dealer or the closest after sales department for more information and the action to do.
13.1. WHEN ENGINE FAILS TO START:
Check if fuel cock is open.
If close, open the fuel cock.
Check fuel level.
If empty, refill fuel tank making sure not to
overfill.
Check if choke lever is in its proper position.
Set the choke lever to CHOKE position.
Check if the key switch of the engine is in the
good position.
If connected, turn off the power switch on the
connected appliance and unplug.
Check to make sure generator is not connected
to an appliance.
If connected, turn off the power switch on the
connected appliance and unplug.
Check spark plug for loose spark plug cap.
If loose, push spark plug cap back into place.
Check spark plug for contamination.
Remove spark plug and clean electrode.
Check the oil level
Add oil
13.2. WHEN NO ELECTRICITY IS GENERATED AT RECEPTACLE:
Check to make sure no-fuse breaker is in the ‘‘l’’
(ON) position.
After making sure that the total wattage of the
electrical appliance is within permissible limits
and there are no defects in the appliance, turn
the no-fuse breaker to the ‘‘l’’ (ON) position.
If breakers continue to actuate, consult your
nearest servicing dealer.
Check AC terminals for loose connection.
Secure connection if necessary.
Check to see if engine starting was attempted
with appliances already connected to generator.
Turn off switch on the appliance, and disconnect
cable from receptacle. Reconnect after generator
has been started properly.