Overload operation will greatly shorten generator service life. If the generator set is
connected to multiple loads or electric appliances, please first connect to one with
the highest starting power, then, the one with the second highest starting power, and
connect others one by one, each with a lower starting power than the preceding one,
finally, connect the one with the lowest starting power.
7.3. dc cUrrENt
dc tErMiNALs
The DC terminals are used to provide power supply
for lower-power DC loads and charging other
batteries. The terminals are colored as such: red
to identify the positive (+) terminal and black to
identify the negative (-) terminal. Load connection
method: The load must be connected to DC
terminals with the proper polarity (load’s positive
to positive DC terminal (red) and load’s negative to
negative DC terminal (black)).
DC Output
dc ovErcUrrENt protEctor
The DC overcurrent protector will automatically
shut off when the DC circuit is overloaded or poor
connection occurs. If the indicator inside the DC
overcurrent protector button pops out, it shows that
the DC overcurrent protector has switched off. Wait
a few minutes and then push the button in to return
to “ON” position.
Circuit Breaker