Relio 4.2.x User Manual – 07/2015
Page 26
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
[email protected] – www.worldcastsystems.com
o
DNS Servers
: DNS configuration. Very important if the Relio is to send e-mails using an
alpha server name (i.e. smtp.server.com as opposed to 54.32.156.67).
o
Current network status
: present network table.
o
Ethernet fail-over:
the Ethernet fail-over function enables the unit to send alarms using
the back-up Ethernet interface in case of issues with the primary interface. The unit
pings the reference address (Always-on IP) at regular intervals (Time between pings). If
there is no answer, the switch takes place. The unit keeps pinging the reference address
and switches back to the primary interface when there is an answer.
When changing the “Time between ping”, the previous time will be applied a last time after update.
!
The Ethernet fail-over function and PPP Dialout are mutually exclusive.
Remember to click the ‘Update’ button in each section to lock in any changes.