Operation
27
GB
After SAleS Support
IRE
0044 151 649 1500
0044 1890 946 244
GB
IRE
47
48
5. Fit a AF 24 ring or open-ended spanner on the fastening nut
47
and an AF 10
open-ended spanner on the drive shaft
48
.
6. Loosen the fastening nut by turning it counterclockwise while holding the drive
shaft tight with the second open-ended spanner.
7. Take the fastening nut and the pressure disc off of the drive shaft.
8. Carefully remove the saw blade from the drive shaft flange diagonally in a down-
ward direction.
9. Clean the drive shaft flange, the fastening nut and pressure disc thoroughly.
10. Place the new saw blade on the drive shaft flange. In the process, observe the di-
rection of rotation: the cutting edge of the blade teeth must point in the direction
of rotation (forward, see the arrow on the protective hood). Usually, the direction
of rotation is indicated on the saw blade.
11. Put the pressure disc back on and screw on the fastening nut by hand.
12. Carefully turn the saw blade in the direction of rotation: It must be exactly centred
and may not “wobble”. Otherwise, you should check to make sure the flange is
properly seated (step 10).
13. Use the two spanners to tighten the fastening nut again.
14. Check and correct the distance between the saw blade and splitting wedge
(see section “Mounting/adjusting the splitting wedge”).
15. Put the insert back in: First insert it on the side facing away from the saw blade in
the groove and then fold it down. It must be flush with the table.
16. Insert the two screws
43