General information

7

General information

Reading and storing the user manual

This user manual accompanies this 50 l compressor (hereinafter referred 

to only as the “compressor”). It contains important information about 

safety, usage and care. 
Carefully read through the user manual before using the compressor. 

Pay particular attention to the safety instructions and warnings. Failure to follow 

the instructions in this user manual may result in serious injury or damage to the 

compressor.
Comply with applicable local or national regulations concerning the use of this 

compressor. Keep this user manual in a safe place for future reference. If you pass the 

compressor on to third parties, please be absolutely sure to include this user manual.

Explanation of symbols

The following symbols and signal words are used in this user manual, on the 

compressor or on the packaging.

 

WARNING!

Indicates a hazardous situation that, if not avoided, 

could result in death or serious injury.

 

CAUTION!

Designates a dangerous situation that may result in 

minor or moderate injury if not avoided.

NOTICE!

Warns against potential damages to property.

This symbol provides you with useful supplementary information on 

assembly or use.

Declaration of conformity (see chapter “Declaration of conformity”): 

Products marked with this symbol meet all applicable Community 

regulations for the European Economic Area.

Read the user manual.

Wear ear protection.

Содержание GPAC2200

Страница 1: ...50 L COMPRESSOR Spend a little Live a lot User Manual Original instructions ID 05007 m y hansecontrol c o m M A N U A L DEVELOPED IN G E R M A N Y User friendly Manual...

Страница 2: ...a website or contact details for example Advantage You do not need to manually enter a website address or contact details How it works To scan the QR code all you need is a smartphone with QR code rea...

Страница 3: ...king the compressor and package contents 16 Preparation 17 Operation 18 Using the compressor 19 Overload protection 20 Cleaning and maintenance 20 Cleaning the compressor 21 Cleaning replacing the air...

Страница 4: ...4 A B C 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 5 5 4 11 23 9 19 22 21 20 9 24 20 21 22 19...

Страница 5: ...5 D G min max H Max 10 I 23 11 12 20 3 13 F 25 5 E 26 4...

Страница 6: ...n cock for condensed water 11 Support foot 2 12 Support foot suspension 2 13 Oil drain plug with viewing window 14 Quick coupling for tank pressure 15 Pressure regulator 16 Quick coupling for control...

Страница 7: ...e place for future reference If you pass the compressor on to third parties please be absolutely sure to include this user manual Explanation of symbols The following symbols and signal words are used...

Страница 8: ...the manufacturer nor the retailer can accept any responsibility for injury loss or damage caused by misuse of this product of any kind Examples of misuse are given in the following non exhaustive list...

Страница 9: ...e compressor and keep the safety instructions in a safe place 1 Keep work area clean and well lit Disorganisation in your work area poses a risk of accident 2 Take any environmental factors into accou...

Страница 10: ...delines Check the mains connection line and the mains plug of the compressor regularly and have it replaced by a qualified professional in case of damage Check the extension cords regularly and replac...

Страница 11: ...n the catalogue may pose a risk of injury for you 17 Have your compressor repaired by an electrical technician This compressor complies with applicable safety regulations Repairs may only be performed...

Страница 12: ...N For your own safety only operate the compressor after you have read the safety instructions WARNING Danger of explosion Operating the compressor in an unsuitable location without adequate venti lati...

Страница 13: ...s on it and never deform it Never operate the compressor if the compressed air tank is damaged or deformed Make sure that the compressed air tank is always vented before separat ing the connections co...

Страница 14: ...ice RCD reduces the risk of electric shock WARNING Burn hazard The compactor and the lines of the compressor may become hot during opera tion You could burn yourself on them Do not touch the compactor...

Страница 15: ...ated handles to transport the compressor Alwayskeepthecompressorinanuprightpositiontopreventoilfromleaking Before each use make sure that there is enough oil in the compressor When the compressor is s...

Страница 16: ...dwithoil whenit isdeliveredto you Ifyoutip the compressortoomuchorplaceitonitsside oilcouldleakoutandcausedamage to property contamination or similar If you operate the compressor with not enough or n...

Страница 17: ...essor is supported and you can mount the wheels 9 on the wheel suspension 24 see Fig A and C 2 Insert the axle screw 19 through the wheel from the outside 3 Insert the open end of the axle screw furth...

Страница 18: ...ds or cable drums could cause a voltage drop and prevent the motor from starting If possible do not use any long feed lines extension cords or cable drums NOTICE Risk of damage If you set up the compr...

Страница 19: ...e maximum pressure generated by this compressor To check the proper function of the compressor fill the compressed air tank with air at maximum pressure after the device has been switched on Using the...

Страница 20: ...pletely 15 Clean the compressor as described in the chapter Cleaning and maintenance Overload protection This compressor is equipped with overload protection In the event of an overload the overload p...

Страница 21: ...ompressor NOTICE Risk of damage Improperorirregularcleaningandmaintenancecoulddamagethecompressor Keep all protective devices vents and the motor housing as free of dust and dirt as possible Clean the...

Страница 22: ...rs This must be done at least once a year if it is operated in a clean environment In dusty environments the filter elements must be replaced more often The manufacturer recommends that you remove the...

Страница 23: ...e manufacturer recommends to regularly drain any condensed water depending on how intensely you use the compressor e g weekly 1 Make sure that the On Off switch 3 is set to the OFF 0 position see Fig...

Страница 24: ...bient temperature of 5 C to 40 C Synthetic oil has the advantage that its character istics remain unchanged at different temperatures e g in the sum mer or winter Checking the oil level Always check t...

Страница 25: ...en ended span ner to tighten it again 9 Add new oil as described in the chapter Adding oil Adding oil 1 Make sure that the On Off switch 3 is set to the OFF 0 position see Fig G 2 Before adding oil pu...

Страница 26: ...anufacturer or its after sales support The mains connection line may only be replaced by a specialist workshop or qualified specialist personnel Checking the compressor Check the condition of the comp...

Страница 27: ...a vehicle Never tip the compressor by more than 10 Always use the handles for transport When transporting the compressor over longer distances carry it on the two handles with the help of another per...

Страница 28: ...room that is not accessible for children Always store the compressor so that it cannot be operated by unauthor ised persons 1 Pull the mains plug out of the socket to disconnect the compressor from t...

Страница 29: ...e motor has over heated The over load protection has triggered Let the motor cool off If necessary rectify the cause of overheating Reset the reset button for the over load protection as described in...

Страница 30: ...regulator more Ordering spare parts Contact the manufacturer at the service address specified on the warranty card if you need spare parts Spare part list Item no Description Spare part number 4 Air f...

Страница 31: ...ection This means it is not permitted to use the device with freely selected connection points In the event of unfavourable grid conditions the compressor could produce tem porary fluctuations in volt...

Страница 32: ...uipment WEEE This product must be disposed of at a designated collection point This can occur for example by handing it in at an authorised collecting point for the recycling of waste electrical and e...

Страница 33: ...rective amended by 2005 88 EC Notified body Soci t Nationale de Certification et d Homologation No 0499 BP23 L 5201 Sandweiler Measured sound pressure level LWA 94 23 dB A K 3 dB A Guaranteed sound pr...

Страница 34: ......

Страница 35: ......

Страница 36: ...its intended use over the course of the first 3 years after date of purchase we will remedy the problem as quickly as possible once it has been brought to our attention In the unlikely event of such...

Отзывы: