28

29

Emergency Stop, and / or failure of On/off Switches  

(NOT RECOMMENDED EXCEPT IN EMERGENCY)

In the case of an emergency that requires the generator to be shut down as 

fast as possible:
1.    Turn “OFF” the 240Va.c Outlet Power On/Off switches (1 and 2). If the 

switches have failed and power is still going to the appliance outlets 

quickly move to step 2.

2.    Press the engine On/Off switch (4) to the “OFF” position as indicated by an 

“O” (Fig. AB). The unit should stop running.  

   If the switches have not shut down the generator, you can quickly remove 

/ pull out the plugs of the appliances plugged into the outlets that need 

to be shut down.

3.    Where the engine keeps operating, don’t panic, turn the fuel lever / tap 

(26) anti clockwise to the “OFF” position (Fig. AA). The generator will run 

out of fuel within one minute and then stop.

   Do not use the generator again until the generator is serviced by an 

authorised service agent and the product is repaired, checked and 

the fault corrected.

As always in an emergency protect people that could be in harms way first. 

Carbon build up

Carbon build up can be a problem on generators as the loading on the  

engine can vary considerably.  Running the generator at low loading for  

extended periods can cause carbon build up.
Carbon build up in the engine can be reduced by operating the generator at 

approximately 75% of rated load for 25% of the time the generator is used. 

i.e, if the generator is used for 4 hours on low load i.e 800W or less, run the 

generator for 1 hour at around 75% of rating. This is only required   

if the generator has been used for less than 25% of rated load for extended  

periods. i.e 2 hrs or more.
NOTE: For best operation and long engine life Use unleaded fuel  

without ethanol. 

Periodic maintenance

Item

Remarks

Pre-operation 

check (daily)

Initial 1 

months 

or 20Hr

Every 3 

months 

or 50Hr

Every 6 

months 

or 100Hr

Every 12 

months 

or 300Hr

Spark plug

Check condition, adjust gap and 

clean. Replace if necessary.

Engine oil

Check oil level.

Replace.

Air filter

Clean. Replace if necessary.

Fuel filter

Clean fuel drain filter. Replace if 

necessary.

Valve clearance

Check and adjust when engine 

is cold.

Fuel line

Check fuel hose for crack or 

damage. Replace if necessary.

Exhaust system

Check for leakage. Retighten or 

replace gasket if necessary.

Check muffler screen. Clean/

replace if necessary.

Carburettor

Check choke operation.

Starting system

Check On/Off switch ignition 

operation.

Decarbonisation

More frequently if necessary.

Fittings/ 

fasteners

Check all fittings and fasteners 

correct if necessary.

Regular maintenance is most important for the best performance and safe operation.

Maintenance

Maintenance

Periodic Maintenance

Содержание 59905

Страница 1: ...ITH PURE SINEWAVE User Manual Product Info www powertoolsupport com Read all safety warnings and all instructions thoroughly before operating this product Ensure you keep your manual in a safe place for future reference IM Ed7 03 2018 ...

Страница 2: ...00W Inverter Generator with Pure SineWave 2 Contents of carton 2 Description of symbols 3 General safety warnings 4 Additional Safety Rules for Petrol Products 6 Risk of electrocution and fire 8 Risk of fire 9 Risk of injury and property damage when transporting generator 10 Risk of breathing inhalation hazard 10 Risk of unsafe operation 10 Risk of hot surfaces 11 Risk of moving parts 11 Risk from...

Страница 3: ...rge protector connected to the generator NOTE This petrol Generator is NOT suitable for Marine applications and should never be used on board water craft Continuous off the grid power Contents of carton 1 x 3600W Inverter Generator 1 x Instruction Manual 1 x Warranty Card details 1 x Quick Start Guide 1 x 10mm Tube Spanner 1 x 21mm Spark PlugTube Spanner 1 x Multi Size Spanner 1 x Double Ended Scr...

Страница 4: ...g power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or key left attached to a rotating part of the power tool may result in personal injuries e Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexp...

Страница 5: ...n operation Ensure bystanders also keep their distance Additional Safety Rules for Petrol Products Locate the generator for use in a convenient place so as to use the shortest extension lead as possible but still sufficiently away from the exhaust fumes Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 10W 30 4 stroke oil Any extension cable...

Страница 6: ...echanical or electrical problem Have unit repaired by an Authorised Service Centre Do not operate generator with protective guarding removed Risk of fire Hazard What could happen How to prevent it Attempting to fill the fuel tank while the engine is running Fuel and fuel vapours can become ignited by coming in contact with hot components such as the muffler engine exhaust gases or from an electric...

Страница 7: ...and understand all of the operating instructions and warnings in this manual Become familiar with the operation and controls of the generator Know how to shut it off quickly Equip area of operation with a fire extinguisher certified to handle fuel fires Keep children or others away from the generator at all times Operating generator while suspended Generator will not operate properly and will caus...

Страница 8: ...ndicator light 9 Power Supply indicator light 10 Muffler 11 Exhaust spark arrestor 12 AC sockets X3 13 Fuel drain 14 Control panel 15 Oil Filler cap dipstick 16 Oil drain plug 17 Ground frame terminal 18 Recoil starter 19 Choke lever 20 Air filter cover 21 Air Filter 22 Spark plug lead cover 23 Spark Plug 24 Tap outlet 25 Fuel tap sediment cap 26 Fuel tap lever 27 Fuel tank inlet filter 28 Feet x4...

Страница 9: ...ding televisions computers laptops caravans etc It comes fitted with 3 x 240V AC outlets giving you the ability to run 3 x electrical appliances at the one time as long as the combination of the maximum rating of each appliance does not exceed the maximum rated power of the generator The maximum operational combination on this generator is 3400W For a short period to aid appliances plugged in star...

Страница 10: ...be spanner 31 to secure the bolt head in position apply the nut onto the end of the bolt and tighten in a clockwise direction using the multi size spanner 33 Fig G Repeat for the second wheel F G E General Assembly General Assembly This generator has been designed to be used as a stand alone compact generator or a larger portable wheeled type generator Compact Stand Alone Assembly Assembly of the ...

Страница 11: ...overheated caused by high temperature c Flashing 3 times indicates overload protection caused by an excessive electrical overload d Flashing 4 times indicates there is an electrical problem most likely caused by a short circuit L M Following assembly of the wheels it is recommended to assemble the additional wheel foot 3 for stability and to keep the generator on a level surface 1 Raise the opposi...

Страница 12: ...Oil NOTE Damage to the engine is not covered under warranty if the engine is run with insufficient oil 1 Before checking or refilling oil be sure the generator is put on a stable and level surface ensuring the engine has been switched OFF 2 Remove the oil filler cap 15 by rotating the cap in an anti clockwise direction and wipe all oil residue off the oil dipstick 15 with a clean rag Re insert the...

Страница 13: ...hen the oil level is close to the low level Fill the oil tank before use each time 4 If the oil is contaminated or has discoloured ensure you change the oil Replace the oil dipstick 15 DO NOT start the generator with the oil dipstick 15 not firmly replaced NOTE This engine is fitted with a low oil indicator light 7 If the oil level is too low the engine will stop operating or the engine will not s...

Страница 14: ...e On Off switch 4 to the ON green position as indicated by an I down Fig U This generator will not start without this switch in the ON position 5 To start the engine slowly pull the recoil starter 18 until you feel it engage and then pull it briskly Fig V When starting the engine for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the ...

Страница 15: ...nue to supply 240Va c output for a very short time but if the load is not reduced the 240V supply will be automatically shut down To reduce load firstly you can stop using one appliance and turn it off see if that rectifies the problem If not refer to page 14 on loading s and how they work If this does NOT solve your problem you will need to reset an overload condition and shut down the engine of ...

Страница 16: ...be a problem on generators as the loading on the engine can vary considerably Running the generator at low loading for extended periods can cause carbon build up Carbon build up in the engine can be reduced by operating the generator at approximately 75 of rated load for 25 of the time the generator is used i e if the generator is used for 4 hours on low load i e 800W or less run the generator for...

Страница 17: ... the fuel totally from the fuel tank 1 Check the fuel tap lever 26 is turned off Fig V Drain and replace the engine oil Clean the generator with a damp soft cloth with mild detergent Do not clean the generator with water Check all nuts bolts and fasteners Ensure they are tightened if needed before storage To ensure the engine is operating correctly the spark plug must be properly gapped and free o...

Страница 18: ...and engine wear It is recommended the air filter 21 is cleaned every 50 hours every 10 hours under dusty conditions ALWAYS keep the filter clean at all times WARNING Ensure the engine is switched off while undertaking this task 1 Remove the air filter cover 20 on the side of the generator using the supplied 10mm tube spanner 30 by removing unscrewing the two screws on the face of the cover in an a...

Страница 19: ... 26 turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Maintenance Cleaning Warranty AK AJ AL LOOSEN TIGHTEN 1 Keep your machine clean The outside of the machine can be cleaned using a damp soft cloth with a mild detergent if required Never use water to clean the generator as it may cause damage to internal parts 2 Some maintenance products and solvents may ...

Страница 20: ...y of your receipt to one of our National Service Agents for repair or call us 1800 909 909 for advice A listing of our Service Agents is included with your product however you can also find our most updated listing on our website www powertoolsupport com by clicking on the Service Agent link Warranty Service Service Environmental protection What your 3 year warranty means Service Support Troublesh...

Страница 21: ...is chart please call Customer Service on 1800 909 909 Troubleshooting Specifications Trouble Possible cause Suggested remedy No electrical output 1 Faulty receptacle 1 Have service centre replace receptacle 2 Overload has been triggered red Overload light on 2 Remove all appliances Stop the generator and restart Reconnect appliances but with reduced load 3 Faulty power cord 3 Have an electrician r...

Страница 22: ... products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 days from the date of purchase for a full refund or replacement or take advantage of our after sales support by calling the supplier s Customer Service Hotline Made in China WORKZONE Titanium is a registered trademark of ALDI Stor...

Отзывы: