You may now move one or both of these switches to the UP “ON” position
depending on how many appliances you are using. A reminder here that
the generator will only power a product or combination of products up to
a maximum of 3400W continually and a little higher 3600W at startup
(Fig Y).
9. As you turn on the appliances and use them it will generate load on the
generator and the engine speed fluctuate as requirements from the
appliances increases and decreases. This is normal.
WARNING: All appliances are rated differently. This generator will work
only with Australian approved rated appliances with an input voltage of
220-240Va.c (Fig Z). Check your appliances meet this requirement on its
rating label before using them. In simple terms if you cant use the product
in your home you definitely cannot use it on this generator.
Overload condition ( Where the appliances want more
power then the generator can provide)
Once operating, If the AC side of the generator becomes overloaded , the
red load status indicator (8) LED will illuminate. The generator will continue
to supply 240Va.c output for a very short time, but if the load is not reduced,
the 240V supply will be automatically shut down. To reduce load firstly you
can stop using one appliance and turn it off , see if that rectifies the problem.
If not refer to page 14 on loading’s and how they work. If this does NOT solve
your problem, you will need to reset an overload condition and shut down
the engine of the generator, however ENSURE to follow the procedure and
thus restart the engine after the load being applied to the generator has
been reduced. Always connect the largest appliance you want to run first
allowing it time to draw current to start . After 20-30 seconds connect the
second appliance.
Normal procedure for Stopping the Engine
(Full shut down and Store)
1. Turn “OFF” the 240Va.c Outlet Power On/Off switches (1 & 2) (Fig R).
2. Remove any appliances connected to either of the 3 outlets (Fig Q).
3. Allow the engine to slow down and idle for approx 15-30 seconds.
4. Press the engine On/Off switch (4) to the “OFF” position as indicated
by an “O” (Fig. U). The unit will stop running .
5. Turn the fuel lever / tap (26) anti clockwise to the “OFF” position (Fig. AA)
Overload procedure for restarting and resetting the engine
1. Turn “OFF” the 240Va.c Outlet Power On/Off switches (1 & 2) (Fig R).
2. Allow the engine to slow down and idle for approximately
15-30 seconds.
3. Press the engine On/Off switch (4) to the “OFF” position as indicated by an
“O” (Fig. AB). The unit will stop running and is shut down. Now follow the
normal starting procedure to restart the generator.
AB.
AA.
ON
OFF
Z.
Operation
Operation