IMportANt: It must be noted that the protective conductor in
electrical systems of appliances may be destroyed by the welding
current in the event of negligence, for example if the earth terminal
is placed on the welding set casing to which the protective conductor
of the electrical system is connected. The welding work is completed
on a machine with a protective conductor connection. It is therefore
possible to weld on the machine without having connected the
earth terminal to it. In this case the welding current will flow from
the earth terminal through the protective conductor to the machine.
The high welding current may cause the protective conductor
to melt.
•
Only fit a 13A fuse in the 13A plug fitted to the supply cable for this welder.
Unplug the appliance before you change its position.
Constricted and wet areas
CAutIoN: When working in constricted, wet or hot areas, use insulating
supports and intermediate layers as well as slip-on gloves made of
leather or other non-conductive materials to insulate your body against
the floor, walls, conductive parts of the machine and the like. If you
use small welding transformers for welding in places with an increase
electrical risk, for example in constricted areas with conductive walls,
(tanks, pipes, etc.), in wet areas (which make work clothes wet) and in
hot areas (perspiration on work clothes), the output voltage of the
welding set when idling must not exceed 48 V (effective value).
Therefore, the appliance may not be used for these purposes because
its output voltage is higher than this.