All amplifier specifications apply to the following settings:  Stereo mode with 8-ohm loads and an 
input sensitivity of 32dB, unless otherwise specified.

Power  Specification
Output Power: 

The following specifications are guaranteed minimums for standard 1 kHz power. 

For more information, see the closed table (maximum average power @ 0.1% THD +N).

Load Impedance: 

Safe with all types of loads. Rated at 4 to 8 ohms in Stereo, 4 to 8ohms in 

Bridge-Mono and 4 to 8 ohms in Parallel-Mono mode.

Required AC Mains: 

Current, frequency and voltage requirements are provided on each unit's 

back panel.

WCE 200: (220/50Hz)

   

8 A of current.

WCE 400: (220/50Hz)

10 A of current.

3.3.1   Drive Protection

The  Drive  Protection  System  temporarily removes output drive to protect the amplifier and its 
loads. Drive Protection System can be activated in two situations. First, if dangerous subsonic 
frequencies or direct current (DC) is detected in the amplifier's output, the unit will activate its 
DC/low-frequency protection circuitry, which puts the amplifier in Drive Protection mode. This  
mode protects the loads and prevents oscillations. The unit resumes normal operation as soon 
as the amplifier no longer detects dangerous output. Although it is extremely unlikely  that  the  
DC/low-frequency protection system will ever be activated, improper source   materials   like 
subsonic square waves or input over-loads, that excessively clip the input signal, can activate 
this system.

The amplifier's protection system will activate the amplifier's  Drive Protection mode in rare 
situations where heavy common-mode current is detected in the output. The unit should 
never output heavy common-mode current  unless its circuitry is damaged. Activating Drive 
Protection mode helps prevent further damage.

3.3.2   Signal Limiting Circuit 

This  internal  limiting  circuit  automatically  reduce  gain  because  of  a  significant  deviation 

between input and output signal flow, preventing occurrence of gross non-linearity conditions 
inside  the  amplifier  caused  by  overdrive,  overload  or  defect,  and  keeps  the  signal  shape 
unaltered under any conditions. The circuit keep signal flow distortion under 0.5%, and thus 
guarantees clean sound and effective speakerprotection. 

                                             6

User Manual/Manual de Uso     WCE 200/400                         

EN

Содержание WCE 200

Страница 1: ...SIG WCE 200 WCE 400 Rev 1 0 User Manual Manual de Uso...

Страница 2: ...NSIDE REFER SERVICING T O Q U A L I F I E D S E R V I C E P E R S O N N E L D I S C O N N E C T POWER CORD BEFORE REMOVING REAR PANEL COVER TO ACCESS GAIN SWITCH Shock Hazard Do Not Enter Choc Hasard...

Страница 3: ...stallation 2 1 Stereo 4 2 2 Mono 4 2 3 RequiredAC Mains 5 3 Operation 3 1 Precautions 5 3 2 Power Indicator 5 3 3 Protection Systems 6 3 3 1 Drive Protection 6 3 3 2 Signal Limiting Circuit 6 4 Specif...

Страница 4: ...acking materials in the unlikely event your unit should ever need to be returned to the factory for service of any kind 1 2 Features Rugged road worthy professional power amplifier E I A Standard 19 4...

Страница 5: ...el In Bridge Mono mode the outputs are wired for twice the output voltage In Parallel Mono mode the inputs are paralleled to link the two channels Bridge Mono mode is provided for loads with impedance...

Страница 6: ...s selecting signal sources and controlling the output level 4 Do not short the ground lead of an output cable to the input signal ground This will form a ground loop and may cause oscillations 5 Do no...

Страница 7: ...fier in Drive Protection mode This mode protects the loads and prevents oscillations The unit resumes normal operation as soon as the amplifier no longer detects dangerous output Although it is extrem...

Страница 8: ...s Stereo Balanced two channel Bridge Mono Balanced single channel Channel 1 inputs are active Both channel volume controls are available Parallel Mono Balanced single channel Channel 1 inputs are acti...

Страница 9: ...zumbidos El triangulo le alerta del riesgo de descargas El punto de exclamaci n le alerta de una instrucci n importante PRECAUCION 8 User Manual Manual de Uso WCE 200 400 Este s mbolo en su equipo o e...

Страница 10: ...nstalaci n 11 2 1 Est reo 11 2 2 Mono 11 2 3 Alimentaci n AC requerida 12 3 Funcionamiento 12 3 1 Precauciones 12 3 2 Indicador de potencia 12 3 3 Protecciones 12 3 3 1 Drive Protection 13 3 3 2 Limit...

Страница 11: ...e embalaje para el hipot tico caso en que sea necesario devolver la unidad 1 2 Caracter sticas Robusto amplificador de potencia profesional en formato de 1 HU rack 19 SIG Indicadores Canal 1 Control d...

Страница 12: ...n de salida En modo Parallel las entradas se conectan en paralelo El modo Bridge se utiliza para cargas superiores a los4 ohmios y el modo paralelo suele usarse con cargas de 4 ohms Bridge mono 1 Gire...

Страница 13: ...n adecuada 3 Use las conexiones con cuidado seleccionando fuentes de se al y controlando niveles de salida 4 No puentee un terminal de masa del cable de salida a un terminal de masa de la entrada Cre...

Страница 14: ...ede activarse en dos situaciones Primera si se detectan frecuencias subs nicas peligros o DC en la salida la unidad activar su circuiter a de protecci n DC baja frecuencia la cual pondr el amplificado...

Страница 15: ...Post rojo negro para conectores tipo banana Modos de se al de salida Estereo Balanceada 2 canales Bridge Mono Balanceada monocanal La entrada del canal 1 est activa ambos controles de volumen est n d...

Страница 16: ...www equipson es EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 equipson equipson es...

Отзывы: