INSTALLATION NOTES

At all times, the amplifier has to be operated under appropriate conditions. This includes that the
operation location provides sufficient ventilation and the device is not exposed to direct sunlight or
direct radiation or reflection from any heat source. Installing the loudspeaker systems choose a location 
that is not affected by extreme and / or constant vibration or other mechanical oscillation. Also make 
sure that the speakers are installed at locations that are free from dust and / or moisture.

CAUTION

Do not take the risk of electro-shock or shock hazard. To reduce the risk of electro-shock, all connections 
have to be accomplished before it is permissible to connect the amplifier to the main supply, Before connecting 
the appliance to the mains supply, once again make certain that all connections are carried out correctly and 
that no short-circuits exist. The overall sound reinforcement installation has to be in accordance to the 
laws, regulations, standards, and guidelines that are relevant and applicable in the country where the 
equipment is going to be operated.

AC POWER SUPPLY CAUTION

Before using the amplifier for the first time, make sure that the appliance's voltage is in accordance to 
your mains supply. Connect the amplifier only to grounded mains outlets. Connecting the amplifler to 
the mains supply(230Vac) has to be accomplished by inserting the supplied mains cord into the 
corresponding socket and afterward plugging it into a mains outlet.

DESCRIPTION

 PA 100 MX 

is the advanced version of . It incorporates 3 LINE inputs (2 rear + 1 front) with selector 

and itsd own volume control, two tone controls and LEDs which mark the signal presence and limit mode.
Additionally, the amplifier incorporates microphone input, providing a mixing function and adding several 
features whivh set the system according to the installation requirements.
The functions that can be set are:

- MIC priority
- Mono/stereo input mode
- 3 gain levels in MIC input
- 3 anti-feedback presets in MIC input

Like PA 100, it can operate with low impedance or 70/100V line loudspeakers.
The operating mode is selected through a switch in the rear side and a dipswitch block which has some 
terminals reserved for future improvements.

In the rear side is allocated a RJ45 connector which admit RS485 commands from an external device in 
order to control some features.

Output Power                      2x 50W @ 8

Ω

 / 100W (70/100V Line)

Audio Inputs                       3 LINE (unbalanced), 1 MIC, 1 RJ45 (RS485 commands)

THD +N       

1 kHz, 15W, 8

Ω/16Ω 

0,1%

1 kHz, 30W, 70V/100V

 

0,2%

Frequency Response            20 Hz-20kHz 0dB - 0.5dB

Main Supply  AC power            230 V - 50/60Hz

Dimensions                                  215x48x264mm(WxHxD)

Weight                                       2.3 kg.

TECHNICAL SPECIFICATIONS

PA 100 MX

Содержание PA 100 MX

Страница 1: ...User Manual Manual de Uso PA 100 MX Rev 16 01 01...

Страница 2: ......

Страница 3: ...om a registered electrician Do not Remove Any Cover Within the product are areas where high voltages may bepresent To reduce the risk of electric shock do not remove any covers unless the AC mains pow...

Страница 4: ...rdance to your mains supply Connect the amplifier only to grounded mains outlets Connecting the amplifler to the mains supply 230Vac has to be accomplished by inserting the supplied mains cord into th...

Страница 5: ...1 in the front side and INPUT 2 3 in the rear panel This stereo minijack connector corresponds to INPUT 1 It accept LINE level Turning all the way to the left mutes the sound Turning all the way to th...

Страница 6: ...5 16 17 Allows to set some functions Check DIPSWITCHES FUNCTIONALITY section RCA type stereo output jack unbalanced output Allows to send preamplified signal to another amplifier EN G L L L R R R SPEA...

Страница 7: ...minals of the loaded speakers terminal to the negative terminals In case of high impedance connection terminals MUST NOT BE CONNECTED Note The speaker output is processed through a high pass lter 80Hz...

Страница 8: ...N SETTING DISABLED ENABLED MIC INPUT PRIORITY MONO STEREO LOW IMPEDANCE MODE INPUT 70V 100V HIGH IMPEDANCE MODE MIC feedback supressor incorporates 3 presets and disable state The 1st preset correspon...

Страница 9: ...a un electricista especializado No retire ninguna cubierta Dentro del producto hay zonas con tensiones altas presentes Para reducir el riesgo de descargas el ctricas no quite las tapas a menos que el...

Страница 10: ...o mediante la inserci n del cable de alimentaci n suministrado en la toma correspondiente y luego conectarlo a una toma de corriente PAGE 8 User Manual Manual de uso DESCRIPCION PA 100 MX es la versi...

Страница 11: ...ando la se al en la salida de los altavoces supera un cierto umbral causando que el limitador se active Tambi n se ilumina si la temperatura interna aumenta de manera inusual Si se activa el limitador...

Страница 12: ...IPSWITCHES Conectores de salidada est reo RCA salida desbalanceada Permite enviar se al preamplificada a otro amplificador PAGE 10 User Manual Manual de uso ES 14 20 15 12 13 16 17 18 19 G L L L R R R...

Страница 13: ...2 canal al terminal de los altavoces En el caso de instalaciones de alta impedancia los terminales NO SE CONECTAN NotA La salida de altavoz est procesada a trav s de un filtro paso alto 80Hz 18dB oct...

Страница 14: ...SUPRESION FEEDBACK Cuerpo del DIPswitch OFF 6 dB 10 dB 15 dB GANANCIA MIC DISABLED ENABLED PRIORIDAD MIC MONO STEREO ENTRADA ST MONO BAJA IMPEDANCIA 70V 100V MODO ALTA IMPEDANCIA MIC supresor feedback...

Страница 15: ......

Страница 16: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 www workproaudio com support workproaudio com...

Отзывы: