SCPRO 4A BL
MANUAL DE USUARIO
VERSION 1.0
BLUELINE DIGITAL MKII SERIES
www.workpro.es
13
Amplified audio output
Power output, dual mode (24Vdc)
2x 15W @ 4
Ω
Power output, Bridge mode (24Vdc)
1x 30W @ 8
Ω
Power output, dual mode (PoE)
2x 5W @ 4
Ω
Power output, Bridge mode (PoE)
1x 10W @ 8
Ω
As can be seen in the chart, we can make a BRIDGE configuration so that the device will
deliver all its power in a single output. Remember that the minimum load in this mode of use
will be 8
Ω
. We will choose the audio extraction mode through WorkCAD3 Configurator.
The different types of connection are detailed below according to the audio extraction mode.
DUAL
BRIDGE
24VDC, 2A power is required to deliver maximum amplifier power.
Check the correct polarity before turning on the power.
The external power supply is not provided with the device.
4.2.6.
Main supply input