This port allows the connection of a BLC 1 wall controller acting as a local command. In this
way, it is possible to select the audio source and control the volume.
Inputs and outputs of general purpose. The device includes 1 GPI and 1 GPO.
-
GPI:
Input used to sense logical voltage variations, so that UDP / OSC control
commands can be sent when they occur. A typical configuration would be the
connection of a push button between GPI and GND, so that when it is pressed or
clicked it can send OSC commands, previously programmed through WorkCAD3
Configurator.
-
GPO: Output in open collector configuration, which once activated allows current to
pass through it. A typical configuration would be the interconnection of a relay coil.
4.2.2.
REMOTE
4.2.3.
GPIOs