Pre-Installation
5
Greenstar 80mm Flexi RF Flue – 6721814542 2019/09
2.2
Flue extension components
Table 3 Extension kit contents
Table 4 90° bend contents
Table 5 45° bends contents
Fig. 3
Extension components
3
Pre-Installation
NOTICE:
Risk of damage to the appliance or flue.
▶ Read all Pre-Installation sections.
▶ Ensure all requirements are met before using the appliance or flue
installation.
Flue gases have a tendency to plume and in certain weather conditions a
white plume of condensation may be discharged from the flue outlet.
Where this could cause a nuisance, for example near security lighting, an
alternate flue position should be found.
The flue terminal positions must also follow those stated in the relevant
appliance installation manual.
For information regarding installation clearances please refer to the
appliance installation manual.
3.1
Chimney requirements
Chimney size
Before starting with the flue installation:
▶ Ensure the cross section of the chimney complies with table 6 and
figure 4.
Table 6 Chimney sizes
Fig. 4
Chimney sizes
Fire resistance
The materials used for the construction of the chimney must be fire
resistant in compliance with the figures stated in table 7.
Table 7 Fire resistance of chimney material
Ø 80/125 1000mm Extension kit
(Part No. 7 719 001 892)
1
Extension tube assembly
Ø 80/125 90° Bend
(Part No. 7 719 001 891)
1
Extension tube assembly
Ø 80/125 45° Bends
(Part No. 7 719 003 665)
1
Extension tube assembly
1
2
3
0010029123-001
C
min
C
max
Ø d
min
Ø d
max
130mm
300mm
146mm
300mm
Type of building
Fire resistance
single storey
30 minutes
multi storey
90 minutes