Installation
Greenstar 80mm Flexi RF Flue – 6721814542 2019/09
12
4.6
Converting the flue outlet
To ease the assembly of the flue components:
▶ Grease all seals lightly with solvent-free grease.
▶ Ensure all seals are seated properly and are in good condition.
1. Fit the flue connector to the appliance.
2. Ensure the connector‘s flat section is at the rear edge of the inner
casing.
Fig. 21 Preparing the appliance
3. Use the screws to refit gasket and blanking plate over the rear flue
outlet.
Fig. 22 Closing the rear flue outlet
4.7
Fitting the flue adaptor
To ease the assembly of the flue components:
▶ Grease all seals lightly with solvent-free grease.
▶ Ensure all seals are seated properly and are in good condition.
1. Fit the flue connector to the appliance.
2. Ensure the connector‘s flat section is at the rear edge of the inner
casing.
Fig. 23 Fitting the flue adaptor to the appliance
3. Secure the connector from inside the inner casing using three
hexagonal bolts.
4. Insert the adaptor through the flue outlet hole on top of the
appliance.
5. Push the adaptor into the appliance flue outlet tube until the retaining
clips secure the adaptor.
Fig. 24 Making the flue connection inside the appliance
0010029154-001
0010029155-001
0010029156-001
0010029157-001