PRE-INSTALLATION
6 720 815 725 (2015/05)
18
3.9
FLUE OPTIONS
The Greenstar CDi Classic
ErP
has the option of three horizontal RSF (60/
100 telescopic, 60/100 longer telescopic and 80/125 telescopic) flue
systems and two vertical RSF (60/100 or 80/125) regular flue systems:
The systems have different maximum flue lengths for different boiler
outputs and different plume management lengths.
For every extra 1000mm of plume management after the first 500mm,
the internal 60/100 flue length must be reduced by 700mm, up to a
maximum of 4500mm of plume management.
For example on a 29CDi Classic
ErP
if the plume management effective
length was 1500mm, the internal flue would be reduced to 5200mm.
This page and the next page show various flue options with the maximum
straight flue lengths allowed to remain within the maximum flue length.
Maximum horizontal flue lengths (L)
Boiler model 100mmØ
125mmØ
No Plume
management
+ 500mm
of plume
management
+4500mm
of plume
management
No plume
management
available
29CDi
ErP
7,900mm
5,900mm
3,100mm
18,500mm
34CDi
ErP
7,000mm
5,000mm
2,200mm
16,000mm
38CDi
ErP
6,000mm
4,000mm
1,200mm
12,500mm
42CDi
ErP
6,000mm
4,000mm
1,200mm
12,000mm
Table 10 Maximum horizontal flue lengths
Maximum vertical flue lengths (L)
Boiler model
100mmØ
125mmØ
29CDi
ErP
9,400mm
18,500mm
34CDi
ErP
8,000mm
16,000mm
38CDi
ErP
7,500mm
16,000mm
42CDi
ErP
7,500mm
16,000mm
Table 11 Maximum vertical flue lengths
NOTICE:
60/100 Flue systems:
▶ Each 90° bend used is equivalent to 1.5 metres of
straight flue.
▶ Each 45° bend used is equivalent to 0.75 metres of
straight flue.
NOTICE:
80/125 flue systems:
▶ Each 90° bend used is equivalent to 2.0 metres of
straight flue.
▶ Each 45° bend used is equivalent to 1.0 metre of
straight flue.
Telescopic horizontal flue
Flue option 1
100mmØ
125mmØ
29CDi
ErP
570mm
600mm
34CDi
ErP
570mm
600mm
38CDi
ErP
570mm
600mm
42CDi
ErP
570mm
600mm
Horizontal extended flue
Flue option 2
100mmØ
125mmØ
29CDi
ErP
7,900mm
18,500mm
34CDi
ErP
7,000mm
16,000mm
38CDi
ErP
6,000mm
12,500mm
42CDi
ErP
6,000mm
12,000mm
Horizontal extended flue with 1x90° bends
Flue option 3
100mmØ
125mmØ
29CDi
ErP
6,400mm
16,500mm
34CDi
ErP
5,500mm
14,000mm
38CDi
ErP
4,500mm
10,500mm
42CDi
ErP
4,500mm
10,000mm
Horizontal extended flue with 2x90° bends
Flue option 4
100mmØ
125mmØ
29CDi
ErP
4,900mm
14,500mm
34CDi
ErP
4,000mm
12,000mm
38CDi
ErP
3,000mm
8,500mm
42CDi
ErP
3,000mm
8,000mm
High level horizontal extended flue
Flue option 5
100mmØ
125mmØ
29CDi
ErP
7,900mm
18,500mm
34CDi
ErP
7,000mm
16,000mm
38CDi
ErP
6,000mm
12,500mm
42CDi
ErP
6,000mm
12,000mm
High level horiz. extended flue with 2x90° bends
Flue option 6
100mmØ
125mmØ
29CDi
ErP
6,400mm
16,500mm
34CDi
ErP
5,500mm
14,000mm
38CDi
ErP
4,500mm
10,500mm
42CDi
ErP
4,500mm
10,000mm
High level horiz. extended flue with 3x90° bends
Flue option 7
100mmØ
125mmØ
29CDi
ErP
4,900mm
14,500mm
34CDi
ErP
4,000mm
12,000mm
38CDi
ErP
3,000mm
8,500mm
42CDi
ErP
3,000mm
8,000mm
Vertical balanced extended flue
Flue option 8
100mmØ
125mmØ
29CDi
ErP
9,400mm
18,500mm
34CDi
ErP
8,000mm
16,000mm
38CDi
ErP
7,500mm
16,000mm
42CDi
ErP
7,500mm
16,000mm
Vertical balanced extended flue with 2x90° bends
Flue option 9
100mmØ
125mmØ
29CDi
ErP
6,400mm
14,500mm
34CDi
ErP
5,000mm
12,000mm
38CDi
ErP
4,500mm
12,000mm
42CDi
ErP
4,500mm
12,000mm
Vertical balanced extended flue with 2x45° bends
Flue option 10
100mmØ
125mmØ
29CDi
ErP
7,900mm
16,500mm
34CDi
ErP
6,500mm
14,000mm
38CDi
ErP
6,000mm
14,000mm
42CDi
ErP
6,000mm
14,000mm