Pre-installation
Greenstar i System
ErP
- 6 720 806 945 (2015/07)
24
4.9.1
Flue lengths
The flue systems have different maximum flue lengths
The Greenstar series has the option of two horizontal 60/100 RSF
(telescopic and longer telescopic) and one horizontal 80/125 RSF
(telescopic) flue system and two vertical RSF (60/100 or 80/125) flue
systems:
Refer to the following example Flue options for the maximum flue
lengths.
Horizontal high level flue assembly
Telescopic horizontal Flue assembly
Extended horizontal flue
Horizontal flue with additional elbow (1 x 90 ° bend)
Horizontal flue with additional elbows (2 x 90 ° bends)
High level horizontal flue
Flue length (mm)
60/100
80/125
Horizontal high level telescopic flue assembly 202 - 603 N/A
Table 16
Flue length (mm)
60/100
80/125
Telescopic horizontal flue assembly
180 - 570
405 - 600
Longer telescopic horizontal flue assembly
570 - 790
N/A
Table 17
Maximum flue length
(mm)
60/100
80/125
Extended horizontal flue
4,600
13,000
Table 18
6720806945-29.1W
o
383 mm - 603 mm
60/100 mm
130 mm Min
6720806945-18.1W
o
350 mm - 570 mm
60/100 mm
130 mm Min
6720806945-19.1W
o
Maximum flue length
(mm)
60/100
80/125
Horizontal flue with 1 x 90° bend
2,600
11,000
Table 19
Maximum flue length
(mm)
60/100
80/125
Horizontal flue with 2 x 90° bends
N/A
9,000
Table 20
Maximum flue length
(mm)
60/100
80/125
High level horizontal flue
4,600
13,000
Table 21
6720806945-20.1W
o
6720806945-21.1W
o
6720806945-22.1W