Fault finding and diagnosis
Greenstar i System
ErP
- 6 720 806 945 (2015/07)
70
8.2
Component resistance characteristics
8.2.1
Flow temperature NTC sensor
8.2.2
DHW NTC sensor
8.2.3
Flue overheat thermostat
8.2.4
Overheat thermostat
8.2.5
Outdoor weather compensation sensor
Resistance (
)
Temperature ( °C)
Measurement tolerance
10%
35,975
0
28,516
5
22,763
10
18,279
15
14,772
20
11,981
25
9,786
30
8,047
35
6,653
40
5,523
45
4,608
50
3,856
55
3,243
60
2,744
65
2,332
70
1,990
75
1,704
80
1,464
85
1,262
90
1,093
95
950
100
Table 50 Central heating flow sensors
Resistance (
)
Temperature ( °C)
Measurement tolerance
10%
36,005
0
28,540
5
22,782
10
18,294
15
14,785
20
11,991
25
9,794
30
8,054
35
6,658
40
5,527
45
4,612
50
3,859
55
3,246
60
2,747
65
2,334
70
1,991
75
1,705
80
1,465
85
1,263
90
1,094
95
951
100
Table 51 Domestic hot water sensors
Normally closed thermostat
Resistance (
) Temperature ( °C)
Opening temperature
3,500
112
Close temperature
6,500
111
Table 52 Flue overheat thermostat
Normally closed thermostat
Resistance
Temperature ( °C)
Opening temperature
50M
120
Close temperature
5,000
119
Table 53 Overheat thermostat
Resistance (
)
Temperature ( °C)
4,111
-40
3,669
-35
3,218
-30
2,775
-25
2,360
-20
1,983
-15
1,650
-10
1,363
-5
1,122
0
922
5
759
10
624
15
515
20
427
25
354
30
296
35
247
40
207
45
174
50
Table 54 Outdoor weather compensation sensor