Fault finding and diagnosis
Greenstar i System
ErP
- 6 720 806 945 (2015/07)
73
8.4
Hot water cylinder function (optional integral diverter valve kit fitted)
Fig. 98 Hot water cylinder operation (optional integral diverter kit fitted)
6720806948-28.2Wo
MAINS
POWER
SUPPL
Y
ON
HOT
W
A
TER
DEMAND
BLUE
LIGHT
ON
Diverter valve
in DHW
position (up)
Pump ON
Fan to
start
speed
Spark
igintion
and gas
4 seconds
90 second
soft start
Fan
modulation
to achieve
set
temperature
(30-82ºC)
Gas valve
OFF
Pump overrun
3 minutes
Fan overrun
30 seconds
Diverter valve
returns to
DHW position
(up) for
DHW priority
Over temperature
shutdown if water
temperature is 6ºC
above set value
Gas valve OFF
.
Fan overrun
30 seconds
W
ait until
temperature
is below set value
LOCKOUT
Stop spark
and gas.
Purge
30 seconds
5th
attempt?
BURNER
LIT?
YES
YES
NO
NO
FLAME
SYMBOL
ON
END OF
HOT
W
A
TER
DEMAND
T
ank
temperature
below setpoint &
demand from
hot water time
control
BLUE
LIGHT
OFF
INIGITION SEQUENCE