![Worcester Greensource 6 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/worcester/greensource-6/greensource-6_installation-manual_996560049.webp)
TECHNICAL INFORMATION
6 720 641 467 (2010/01)
49
15.2 TECHNICAL DATA
Heat pump
6
7
9.5
Output/input at +7/35°
1)
1) Output details in accordance with EN 14511.
kW
5,43 / 1,50
7,27 / 2,20
8,36 / 2,45
Output/input at +2/35°
2)
2) Output details in accordance with EN 14511.
kW
4,56 / 1,45
6,13 / 2,16
7,14 / 2,41
COP at +7/35º
3,62
3,31
3,41
COP at +2/35º
3,15
2,83
2,96
Nominal flow rate, refrigerant
l/s
0.19
0.29
0.34
Internal pressure drop, refrigerant
kPa
5
6
7
Air flow rate
m
3
/h
2200
Power consumption, fan motor
A
0.44
Power supply
230V 1N~ 50Hz
Fuse rating
3)
3) Safety fuse type gL-gG or MCB type C.
AT
16
25
25
Starting current (softstart)
A
23,43
30,56
32,05
Compressor
Scroll
Compressor oil
FV 50S
Lowest/highest outgoing heat carrier temperature
°C
20/65
Refrigerant mass R-407C
4)
4) Global warming potential; GWP
100
=1526
kg
2.5
2.6
2.95
Connection, refrigerant
Hose 1 inch internal thread
Defrost system
Hot gas with 4-way valve
Operating temperature
°C
-20 – +35
5)
5) Tested at -17°C according to the European standard EN 14511-4.
Dimensions (WxDxH)
6)
6) Dimensions excl. adjustable feet; subject to adjustment plus 20 mm (minimum) - 30 mm (maximum).
mm
840 x 665 x 1223
Weight
kg
140
144
152
Outer casing
Zinc-plated painted sheet steel