TECHNICAL INFORMATION
6 720 641 467 (2010/01)
46
15 TECHNICAL INFORMATION
15.1 FACTORY SETTINGS
The table displays the factory values (F value) of the
settings that you, as a customer, (K) can change via the
customer menus
Menu
and
Advanced menu
.
The menu points in the installation and service menus (I/
S) listed in the following table become accessible to the
installer after changing the
Access level
, either under
menu or under
Advanced menu
.
Menu
Level
F-value
Fast restart of heat pump?
I/S
No
Start up
_“_\Setting the clock
_”_\_”_\Set date
I/S
YY-MM-DD
_”_\_”_\Set time
I/S
hh:mm:ss
_”_\Connected extra sensors
_”_\_”_\T5 confirms (room temperature
sensor T5)
I/S
No
_”_\Air/Water pump in operation
I/S
Yes
_”_\Connection capacity (electric element)
_”_\_”_\State total output
I/S
13.5 kW
_”_\_”_\Compressor mode, output limita-
tion
I/S
4.5/6.75 kW
_”_\_”_\Additional heat only, output limita-
tion
I/S
9.0/13.5 kW
_”_\Manual operation?
I/S
No
_”_\Additional heat options
_”_\_”_\Additional heat only?
I/S
No
_”_\_”_\Block additional heat?
I/S
No
_”_\Language
I/S
Selected
_”_\Correct sensor
I/S
0
_”_\Fan defrost interval
I/S
1 ggr
_”_\Fan defrost time
I/S
1.0 min.
_”_\Forced defrost
I/S
No
_”_\Block crankcase heater at high out-
door temperature
I/S
10.0 °C
_”_\Anti-jamming mode time
I/S
02:00
_”_\Alarm buzzer signal length
I/S
1 min.
_”_\T1 Set point value maximum
I/S
80 °C
_”_\Display
_”_\_”_\Contrast
I/S
10
_”_\_”_\Brightness
I/S
10
Tab. 7
_”_\Electrical connection
I/S
230V/400V
_”_\Heat pump size
I/S
6-11kW/
12-17kW
Room temperature setting (T5)
K
20°C
Temperature increase/decrease (T5)
K
=
Temperature increase/decrease settings (T5)
_”_\Limit value for V or H
I/S
2 °C
_”_\Change when much colder/warmer
I/S
8%
_”_\Change when colder/warmer
I/S
3%
Extra hot water
K
0 h
Temperatures
K
Advanced menu
Level
F-value
Temperature
_”_\Lowest outdoor temperature
K
20 °C
_”_\Heating system temperature
_”_\_”_\Heat curve
K
V=20.0 °C
H=45.6 °C
_”_\_”_\Hysteresis
_”_\_”_\Maximum
K
16 °C
_”_\_”_\Minimum
K
4 °C
_”_\_”_\Time factor
K
10
_”_\Room sensor settings (T5)
_”_\_”_\Room temperature setting
K
20 °C
_”_\_”_\Room sensor influence
_”_\_”_\_”_\Change factor
K
5.0
_”_\_”_\_”_\Blocking time
K
4 h
_”_\Time limited settings
_”_\_”_\Time control heating
_”_\_”_\_”_\Day and time
K
Off
_”_\_”_\_”_\Change in temperature
K
-10 °C
_”_\_”_\Holiday
_”_\_”_\_”_\Date
K
Off
_”_\_”_\_”_\Change in temperature
K
-10 °C
_”_\_”_\Remote control
_”_\_”_\_”_\Remote control
K
Off
_”_\_”_\_”_\Change in temperature
K
0 °C
_”_\External control heating
K
Off
Tab. 8
Menu
Level
F-value
Tab. 7