HEATING SYSTEM CONNECTION
6 720 641 467 (2010/01)
19
7.9
CONNECTION PRINCIPLE OF THE
INTERNAL UNIT
The principle method of operation is based on the
vapour compression cycle with any additional heat being
provided by the built in electric heater. The control unit
regulates the heat pump in accordance with the set
heating curve with the actual temperatures captured by
outside temperature sensor T2 and flow temperature
sensor T1.
When the heat pump can no longer meet the entire
heating demand on its own, the electric additional heat
in the internal unit starts and generates the temperature
required inside the building together with the heat
pump.
DHW heating has priority. DHW is regulated by means of
the actual temperature captured by cylinder
temperature sensor T3. Heating is switched off via the 3-
way valve when the DHW cylinder is being heated up.
The heating system will be supplied with heating water
again once the DHW cylinder has reached its set
temperature.
Operation in extreme cold conditions:
At an outside temperatures below approx. – 20 °C, the
heat pump stops automatically and can no longer heat
DHW. Under those conditions, the additional electric
heater in the internal unit automatically takes over the
DHW heating.
Fig. 19 Internal unit
Q46
E10 Radiator
system
C11 Expansion
vessel
C12
Primary water storage tank*
G1A Heating
system
pump
G1B
** Heating
system
pump
P11 Pressure
gauge
Q10 Mixing
valve
Q12 Isolating
valve
Q13 Water
outlet
E20 Heating
system
E21 Heat
pump
F21 Safety
valve
G2
Heat carrier pump
G3 Fan
Q20 3-way
valve
Q21 3-way
valve
Q22 Air
vent
V21 Filter
heating
system
E40 Tap
water
system
C41 Expansion
vessel
E41
Hot water cylinder
V40 Hot
water
W40 Cold
water
F42 Temperature
&
pressure
relief
valve
Q42 Isolation
valve
Q43 Pressure
reducing
valve
Q44 Non
return
valve
Q45 Tundish
Q46 Blending
valve
Sensors
T1 Heating
system
sensor (indoor unit)
T2 Outdoor
sensor
T3 DHW
sensor
T5 Room
sensor
T6 Hot
gas
sensor
T8 Heat
pump
sensor
(outdoor
unit)
T9
Heat pump return sensor
(indoor
unit)
T10 Condenser
T11 Evaporator
temp.
T12 Air
intake
primary water storage tank is not required
** G1B is not supplied and should only be used in conjunction with the Primary water storage tank.