Supplied By www.heating spares.co Tel. 0161 620 6677
RECTIFYING FAULTS
8 716 115 748 (2009/09)
44
EA
and RESET button and fault indicator LED are flashing.
During operation: flame not detected.
Check
Action
1.
Is a burner flame visible?
yes:
go to 5
no:
go to 2
2.
Is the gas cock turned on?
yes:
go to 3
no:
B
Open the gas valve.
B
Press the
reset
button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 3
3.
Is there air in the supply pipe?
yes:
B
Vent supply pipe
.
B
Press the
reset
button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 4
no:
go to 4
4.
Natural gas models
:
measure gas supply at gas valve. Is the
pressure OK according to
technical data?
yes:
B
Is correct code plug fitted? If not, fit correct code
plug (see Appendix).
B
Press the
reset
button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 5
no:
B
Check working pressure at appliance to eliminate
pipe work problems.
B
Check pressure at the building supply pressure
regulator, inform gas company if outside correct
range.
B
Press the
reset
button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 5
LPG models:
is the flow rate of the gas supply to the
appliance correct?
yes:
go to 5
no:
B
Is there enough gas in the supply cylinder?
B
Is there air in the supply pipe?
B
Is the supply pressure OK? (if supply pressure out-
side correct range, inform gas supplier)
B
Press the
reset
button for 3 seconds and release it.
After releasing the appliance re-starts.
EA? go to 5
Tab. 25 EA Error codes