background image

Woodway Engineering Ltd 

Lower Road, Barnacle

Coventry, CV7 9LD

United Kingdom

Tel:  +44 (0) 24  76 841750 

Fax:  +44 (0) 24  76 621796

[email protected]

www.woodwayengineering.com

I N S T A L L A T I O N   G U I D E

4

System Operation

Keypad Switches 1-13

Light Bar 360 Function

Other Features

Power Down and Wake Up Modes

Power Down and Wake Up Modes

Audible and Visual Warnings

999 / Arrival / Reset Switch

The Keypad has 12 standard control switches, 1 siren control switch and a 999/arrival/reset switch. Pressing any standard switch will 

give a corresponding output from the Output/Receiver. i.e. SW1 will switch channel 1 on the Output/Receiver, SW2 channel 2 etc. The 
siren switch operates channel 13. Switches 1-12 can be set to latching or momentary operation. Switch 1 and 2 are intended to be 

used as a light bar front/rear/360 utility as detailed below. The siren switch is only latching. Latching switches once pressed remain 

active until pressed again; momentary switches are active only when pressed.

Switches 1 and 2 are assigned for use with a light bar. Switch 1 activates the front of the light bar and switch 2 the rear. When both 

switches are clear, hold switch 1 for 0.5 seconds and it will activate both channel 1 and 2 giving the user a 360 function with one 
button press. When in 360 mode, hold switch 1 for 0.5 seconds and the keypad will de-activate both channels 1 and 2. The buttons 

operate as normal in all other situations.

A bank of switches can also be set as ‘self-cancelling’, which means that only one button in the bank can be active at any one time. The 

keypad has a permanent backlight for low light viewing and each active latching switch is illuminated further when active. Momentary 
switches are illuminated only when pressed. Under low light conditions a light sensor will lower the illumination intensity of all active 
switches to prevent driver distraction. The sensor for this is situated at the bottom of the keypad and should not be covered if the 

Auto Dim feature is to function. Keypad legends can be factory fitted according to the customer’s requirements or customer fitted. 

Soft switching prevents large current surges on the vehicle electrical system by staggering the programmed switch activation.

When the battery supply falls below 12 volts, providing no channels are selected, the power down timer will start up. After 20 minutes 

the unit will power down and disable the keys back lighting. The unit will ‘wake up’ when a key is pressed or when the battery voltage 

rises above 13 volts.
When the unit is asleep, pressing any key will wake the unit up but won’t turn that channel on. This allows the acts of waking and 

operating a channel a separate action. The 999/arrival/reset key will however wake the unit up and activate the pre-programmed 

respond mode, allowing a quick response if required.
If the battery is at or below 12 volts, pressing and holding the reset and siren keys together will put the unit to sleep. If the voltage is 
too high, the unit will emit a long beep indicating to the user that the switch panel system can’t go to sleep.

The Keypad incorporates a public address microphone for use with a Woodway siren with PA capability and is made active via a PTT 

(Press-To-Talk) switch located on the right hand side of the keypad. When the switch is operated it will mute any active siren tones. 
The volume is factory set to 50% but may be adjusted to suit operator preferences via the keypad. 

As a reminder that the panel is active, the LED at the top of the panel will flash and the system will beep every 30 seconds.

• 

The 999/arrival/reset switch will automatically change its function between three modes of operation:

•  Reset; when a key is selected manually or via the arrival button, pressing this key will clear any selected channels.
• 

999; when the keypad is clear, pressing this button will activate the pursuit channels. A blue LED will light below the button to 

indicate this mode is active.

• 

Arrival; when the keypad is in pursuit (999) mode, pressing this button moves the selection to the preset arrival mode. A red LED 

will light to indicate that the keypad is in arrival mode. Pressing the button again will clear all channels (reset).

• 

Walk test; holding the 999/arrival/reset button for two seconds will activate an automatic walk test. This will turn on each channel 

consecutively for five seconds allowing the user to check the operation of each device on the system. The first channel will stay lit 
for fifteen seconds to allow the user time to exit the vehicle. Press the reset button to cancel the walk test at any time.

Содержание Opti-Din

Страница 1: ...y Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE Opti Din H...

Страница 2: ...s manual Disclaimer Important Installation and Safety Notes CAUTION Modules and connectors are not waterproof Install modules and cables in a dry location away from excessive heat humidity and any com...

Страница 3: ...g The switch outputs from the Output Receiver Module interface directly with the low current control wiring of Woodway supplied light bars sirens and strobe power supply systems The outputs may be use...

Страница 4: ...aggering the programmed switch activation When the battery supply falls below 12 volts providing no channels are selected the power down timer will start up After 20 minutes the unit will power down a...

Страница 5: ...amming or press 999 arrival reset again to reset the keypad then the keypad button press above can be performed to return to normal operation To reprogram the arrival activated channels follow the pro...

Страница 6: ...g mode press and hold the channel 6 selection key and repeat the operation above If more than one self cancelling group channel is incorporated as part of a 999 or arrival selection all channels will...

Страница 7: ...s not flashing Communication fault Check data link connections are secure Check fuse Check voltage Check switch panel is plugged in Is the switch panel damaged or otherwise non functional High pitch w...

Страница 8: ...CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 8 System Installation Wiring Diagrams 1 2 3 4 5 6 7 8 9 1...

Страница 9: ...OUTPUT RECEIVER RELAY CONNECTIONS Socket SK3 Pin Wire Colour Function 1 Figure 5 2 3 White Orange Hands Free Plug P3 Pin Function Wire Colour 1 2 3 White Orange Hands Free Socket SK4 Pin Wire Colour...

Страница 10: ...odway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 10 Note...

Страница 11: ...odway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 11 Note...

Страница 12: ...ring Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com Made in the UK ISO 9001 2015 Certified...

Отзывы: