Manual 35076
LESV II
Woodward
49
Symptom Possible
Causes
Remedies
Upon enabling, valve will open
and then fail closed
Resolver sine and cosine wires
are swapped, and sine wires
high and low are flipped
Conduct continuity check.
Resolver sine and cosine wires
are swapped, and cosine wires
high and low are flipped
Conduct continuity check.
Poor flow accuracy
Characterization data in engine
control does not match the valve
Verify characterization data
matches the valve serial
number.
Build-up of contamination on the
seat
Remove valve and inspect flow
elements.
Poor position stability
One motor wire disconnected Conduct
continuity check.
Valve stem resolver indicates
position error
Incorrect parameter file loaded
Verify the parameter file
matches the valve serial
number.
Valve stem resolver wires not
properly connected between
DVP and actuator
Contact manufacture for
instructions or return to
manufacturer for repair.
Faulty resolver
Return to manufacturer for
repair.
Drive train failure
Return to manufacturer for
repair.
High overboard vent leakage
Internal seals damaged
Return to manufacturer for
repair.
High seat leakage
Damage to valve seat or plug
Remove valve and inspect flow
elements. Return to
manufacturer for repair.
Contamination buildup in seat or
plug
Remove valve and inspect flow
elements. Return to
manufacturer for repair.
Valve not fully closed
Remove valve and verify plug is
not properly seated. Return to
manufacturer for repair.
External gas fuel leakage
Piping flange gaskets missing or
deteriorated
Replace gaskets.
Piping flanges improperly
aligned
Rework piping as needed to
achieve alignment requirements
detailed in Chapter 3.
Piping flange bolts improperly
torqued
Rework bolts as needed to
achieve torque requirements
detailed in Chapter 3.
Packing missing or deteriorated
Return actuator to Woodward for
service.
SIL2 sensor output
out of range at 0 %
or 100 % travel (see
specifications)
Piping flange gaskets missing or
deteriorated
Replace gaskets.
Incorrect sensor wiring
Verify supply voltage and sensor
output connections are correct.
Incorrect supply voltage
Verify sensor supply voltage is
within specifications.
Faulty sensor
Install replacement sensor.
Released
Содержание Large Electric Sonic Valve II
Страница 14: ...Manual 35076 LESV II Woodward 12 Figure 1 1 Optional SIL2 Flow Sensor 3 4 6 inch LESV II Released...
Страница 15: ...Manual 35076 LESV II Woodward 13 Figure 1 2a Outline Drawing 2 Inch LESV II UHR SST 600 Dual Resolver Released...
Страница 16: ...Manual 35076 LESV II Woodward 14 Figure 1 2b Outline Drawing 2 Inch LESV II UHR SST 600 Dual Resolver Released...
Страница 17: ...Manual 35076 LESV II Woodward 15 Figure 1 3a Outline Drawing 3 Inch LESV II Class 600 Released...
Страница 18: ...Manual 35076 LESV II Woodward 16 Figure 1 3b Outline Drawing 3 Inch LESV II Class 600 Released...
Страница 19: ...Manual 35076 LESV II Woodward 17 Figure 1 4a Outline Drawing 4 Inch LESV II Class 600 Released...
Страница 20: ...Manual 35076 LESV II Woodward 18 Figure 1 4b Outline Drawing 4 Inch LESV II Class 600 Released...
Страница 21: ...Manual 35076 LESV II Woodward 19 Figure 1 5a Outline Drawing 6 Inch LESV II Class 600 Released...
Страница 22: ...Manual 35076 LESV II Woodward 20 Figure 1 5b Outline Drawing 6 Inch LESV II Class 600 Released...
Страница 40: ...Manual 35076 LESV II Woodward 38 Figure 3 11 Cable Motor Resolver 1 Feedback Signal Released...
Страница 41: ...Manual 35076 LESV II Woodward 39 Figure 3 12 Cable Stem Shaft Resolver LVDT Feedback Signal Released...
Страница 42: ...Manual 35076 LESV II Woodward 40 Figure 3 13 Cable Motor Resolver 2 Feedback Signal Released...
Страница 43: ...Manual 35076 LESV II Woodward 41 Figure 3 14 Cable Motor Power 2 Inch LESV II LELA1 with DVP5k Released...
Страница 63: ...Manual 35076 LESV II Woodward 61 Declarations Released...
Страница 64: ...Manual 35076 LESV II Woodward 62 Released...
Страница 65: ...Manual 35076 LESV II Woodward 63 Released...