Single-phase motor 230 V / 50 Hz
Mains voltage 230 V / 50 Hz
%XTENSIONCABLESMUSTBELEAD0.3,.0%
Extension cables must have a minimum cross-section of
1.5 mm².
Mains fuse protection is 16 A maximum.
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
-AINSVOLTAGEANDEXTENSIONCABLESMUSTBELEAD0
.3,.0%
Extension cables must have a minimum cross-section of
1.5 mm².
Mains fuse protection is 16 A maximum.
When connecting to the mains or relocating the machine,
check the direction of rotation (swap polarity in the wall
socket if necessary).
Turn pole inverter in the machine socket.
Maintenance and repair
Switch off the motor and pull the power supply plug be-
fore undertaking any converting, maintenance, or clean-
ing work.
Always pull power plug!!
Skilled craftsmen can execute smaller repairs on the ma-
chine themselves.
Repair and maintenance work on the electrical system may
only be carried out by an electrician.
All protection and safety devices must be replaced im-
mediately after completing repair and maintenance pro-
cedures.
We recommend:
s 4HOROUGHLYCLEANTHEMACHINEAFTEREVERYUSE
s
Splitting knife
The splitting knife is a wearing part that should be
reground or replaced by a new one, if necessary.
s
Two-hand control
The combined supporting and control unit must be
kept easy-going. Occasionally grease with a few drops
of oil.
s
Moving parts
Keep splitting knife guides clean from dirt, wood chips,
bark etc.
Grease sliding rails with oil spray or grease.
s
Checking the hydraulic oil level
Check hydraulic connections and bolts for tightness
and wear. Retighten the bolts if necessary.
Checking the oil level
The hydraulic unit is a closed system with oil tank, oil
pump and control valve. Check the oil level regularly be-