background image

1.  Plunger Assembly with Audio Alarm (WBP)

2.  Plunger Cap with Sound Emission Holes

3.  AAA Battery

4.  Red Line

5. U-Cup

PLUNGER 

ASSEMBLY WITH

LOW VACUUM 

AUDIO ALARM

See overleaf for SPECIFICATIONS, OPERATION, MAINTENANCE and 

WARNINGS. 

TO INSTALL PLUNGER ASSEMBLY

Grasp the head of the old plunger assembly and 

pull it straight out from the handle. If the plunger 

assembly is too tight to be removed this way, 

return the hand cup for repair.

Wrap a small dowel or rod with a soft, lint-free 

cloth and wipe the inside of the handle, to 

make sure it is clean and dry (lubricant-free). 

Carefully examine the inside of the handle for 

scratches and contaminants, using a flashlight 

for illumination. Scratches between the mid-

point and the closed end of the handle can cause leakage. Scratches near the 

open end of the handle rarely present a problem. Make sure that no old lubricant 

remains inside the handle.

Using a soft swab, apply a ring of new lubricant 

around the inside of the handle, at a point about 1" 

[25 mm] from the closed end. Keep the open end 

of the handle as dry (lubricant-free) as possible. 

Silicone lubricant is recommended; contact Wood's 

Powr-Grip Customer Service to order this. Do not 

use improper lubricants in the handle.

Insert the U-cup 

end of the plunger 

assembly into the 

handle, and push 

until the plunger assembly begins to tighten; 

then seat the plunger assembly with one strong, 

swift motion. Operate the plunger, turning it to 

spread the lubricant thoroughly on the U-cup. 

Then leak-test the hand cup as directed in the 

following section.

TO LEAK-TEST HAND CUP

Attach the hand cup to a clean, smooth, scratch-free piece of glass or metal for 

approximately 2 hours. The audio alarm and the red line on the plunger serve as 

low vacuum indicators: If the audio alarm 

does not

 sound and red line 

does not

 

appear during the test period, the cup is usable; if the audio alarm 

does

 sound 

or the red line 

does

 appear, discontinue use until the problem is corrected. See 

MAINTENANCE: Service (overleaf) for more instructions.

TO REPLACE BATTERY

Test the audio alarm regularly (see OPERATION: To Test Audio Alarm, overleaf) 

and replace the battery as necessary. CAUTION: Follow the battery manufacturer’s 

instructions for correct handling, storage and disposal of batteries.

1)  Hold the plunger and turn the plunger cap counter-clockwise to loosen it.

2)  Remove the plunger cap and the old battery.

3)  Install a new battery in the battery chamber, making sure to orient the positive  

  end (+) toward the red line and the negative end (-) toward the plunger cap. 

  CAUTION: Do not reverse battery polarity, because the audio alarm will not 

 function.

4)  Reinstall the plunger cap, turning clockwise to tighten it securely.

LIMITED WARRANTY

Wood’s Powr-Grip vacuum cups are carefully constructed, thoroughly inspected 

at various stages of production, and individually tested. They are warranted to 

be free from defects in workmanship and materials for one year from the date of 

purchase. If a problem develops during the warranty period, return the complete 

product as directed below. If inspection shows that the problem is due to defective 

workmanship or materials, the product will be repaired or replaced without charge.

WARRANTY DOES NOT APPLY WHEN:

Rubber portions have been cut or scratched during use.

Repairs are required due to abnormal wear and tear.

The product has been abused, misused or neglected.

Alterations have been made to the product.

A problem not covered under warranty will be corrected automatically, unless the 

customer includes a written request for notification of costs prior to repair. Otherwise 

the customer assumes all responsibility for repair costs and agrees to receive the 

repaired product on a C.O.D. basis.

TO OBTAIN WARRANTY SERVICE

For purchases in 

North America

:

 

•   Please include your name, address and phone number;

 

•   Indicate WARRANTY RETURN;

 

•   Ship product–prepaid–

DIRECTLY TO MANUFACTURER

 at:

 

Wood’s Powr-Grip Co., Inc.

 

908 West Main

 

Laurel, MT 59044 U.S.A.

For purchases in 

all other localities

:

 

•   Return product to point of purchase

.

Purchased From

Date Purchased

Model No. 

Serial No. (if present)

RETAIN THIS INFORMATION FOR YOUR RECORDS. 

Installation

Limited Warranty

Содержание LJ6VHWBP

Страница 1: ...rt 2 Pull one of the release tabs on 6 153 mm cups or press the valve release lever on other cups until the cup disengages completely CAUTION Remove the cup when not in use MAINTENANCE Service Since aging and wear reduce the capacity of the rubber pad it should be replaced at least once every 2 years or whenever damage is discovered see Inspection If the audio alarm does not function normally see ...

Страница 2: ...CE Service overleaf for more instructions TO REPLACE BATTERY Test the audio alarm regularly see OPERATION To Test Audio Alarm overleaf and replace the battery as necessary CAUTION Follow the battery manufacturer s instructions for correct handling storage and disposal of batteries 1 Hold the plunger and turn the plunger cap counter clockwise to loosen it 2 Remove the plunger cap and the old batter...

Страница 3: ... está escondida y la alarma audible está silenciosa de nuevo véase ADVERTENCIAS Desprender la ventosa de mano 1 Ponga la carga sobre un soporte seguro 2 Tire de una de las pestañas de desprendimiento para ventosas de 6 15 cm u oprima la palanca de desprendimiento para otras ventosas hasta que la ventosa se desprende por completo PRECAUCIÓN Quite la ventosa cuando no está en uso MANTENIMIENTO Servi...

Страница 4: ...Prueba la alarma audible con regularidad véase FUNCIONAMIENTO Probar la alarma audible al dorso y reemplace la batería según lo necesario PRECAUCIÓN Cumpla con las instrucciones del fabricante para manejar almacenar y desechar las baterías 1 Agarre el émbolo y vuelva el tapón del émbolo en el sentido contrario a las manecillas del reloj para aflojarlo 2 Quite el tapón del émbolo y la batería exist...

Страница 5: ...es Handsaugers 1 Legen oder stellen Sie die Last auf eine sichere Stütze 2 Ziehen Sie an einem der Löselaschen bei 6 15 cm Saugern oder halten Sie den Ventil Lösehebel gedrückt bei anderen Saugern bis der Sauger vollständig gelöst ist VORSICHT Entfernen Sie den Sauger wenn dieser nicht benutzt wird WARTUNG Instandhaltung Da die Tragfähigkeit des Gummisaugertellers durch Alterung und Abnutzung beei...

Страница 6: ...ing sichtbar wird unterbrechen Sie den Gebrauch bis das Problem behoben ist Für zusätzliche Anweisungen konsultieren Sie WARTUNG Instandhaltung umseitig ERSETZEN DER BATTERIE Prüfen Sie die akustische Alarmanlage regelmäßig siehe BEDIENUNG Prüfen der akustischen Alarmanlage umseitig und ersetzen Sie die Batterie bei Bedarf VORSICHT Befolgen Sie die Anleitungen des Batterie Herstellers zur korrekte...

Страница 7: ...dio soit silencieuse de nouveau voir AVERTISSEMENTS Dégager la ventouse à main 1 Posez la charge sur un support solide 2 Tirez sur une des pattes de dégagement des ventouses de 6 po 15 cm ou appuyez sur le levier de dégagement des autres ventouses jusqu à ce que la ventouse se détache complètement ATTENTION enlevez la ventouse quand elle n est pas employée ENTRETIEN Révision Puisque le vieillissem...

Страница 8: ...lème soit rectifié Voyez ENTRETIEN Révision au verso pour trouver des instructions supplémentaires REMPLACER LA BATTERIE Testez l alarme audio régulièrement voir MODE D EMPLOI Tester l alarme audio au verso et remplacez la batterie au besoin ATTENTION suivez les instructions du fabricant de la batterie pour manier emmagasiner et éliminer des batteries correctement 1 Saisissez le piston et tournez ...

Отзывы: