background image

Operating instructions

GB

Wood´s the world´s leading Dehumidifiers

Wood’s dehumidifiers have been recognized as market leaders for many years. Wood’s dehumidifiers are suitable for 

use in the most demanding climates, and have high dehumidifying capacity even at lower temperatures and humidity 

levels. They are used with good results in premises that become damp such as cellars, garages or summer-houses 

etc. They are also excellent for drying washing, attics, pool rooms and laundry, being efficient and low on energy con-

sumption. Wood’s dehumidifiers will dry your clothes efficiently without wearing them out.

The amount of humidity that the dehumidifier removes depends on temperature, humidity level and placement. Ex-

ternal weather conditions may also affect the performance of the dehumidifier. In cold weather the actual humidity, (in 

grams per cubic meter air) decreases and thus the extraction of humidity from the air by the dehumidifier is reduced. 

Therefore the dehumidifier is suitable for use in the temperature range +5˚C to +35˚C. Wood’s dehumidifiers are safe 

in operation and intended for continuous use over many years.

Excessive Air Humidity-a danger.

Condensation occurs when water vapour in the air comes into contact with a cold roof, window or wall. When water 

vapour is cooled down, condensation occurs, and water-drops are formed. In high air humidity, the air may get musty 

and mould is formed, causing damage to a house and its furnishings. This environment may even cause illness for the 

residents, since mites and other creatures thrive in a damp environment. A dehumidifier with high performance creates 

a good, healthy humidity level, and for greatest efficiency the doors and windows of rooms that are being dehumidified 

should be kept closed. Wood’s dehumidifiers remove odours, dries wood and remove moisture from sportswear out-

doors equipment. A dehumidifier may be used in cellars, washrooms, garages, crawl spaces, caravans, summer-hous-

es and on boats. If the dehumidifier is kept in colder environments, you should study the Hints at the end of the manu-

al.

Placement of your Dehumidifier.

Wood’s dehumidifiers are easy to move around, all you need to have is a power source for 220/230V, but keep in 

mind the following:

- The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will 

reduce performance.

- It is beneficial to use a radiator or heating fan to keep the temperature above +5˚C.

- The dehumidifier should stand at least 25cm from a wall or other obstruction, for maximum air flow.

- Ideal is to put it in the centre of the room / area.

Hints:

- When the dehumidifier is used in extremely damp environments or when the temperature is below +10˚C, the dehu-

midifier may stop working. A large amount of ice may build up on the cooling coil. Turn off the dehumidifier and place it 

a little above floor level so that the ice will melt away.

- For maximum dehumidification in a room it is recommended that the air supply from outside and from a near room  

  be minimized - close doors and fans.

- Increase temp. for faster dehumidification ( warm air liftes and carries more water.)

- Higher dehumidification in Autumn / Summer because outside air is warm and humid.

- If the power is stopped suddenly, the machine will remain shut off for 3 minutes before restarting automatically when 

the power returns.

Содержание DSC-90ES

Страница 1: ...DEHUMIDIFIER GB S Operating instructions Bruksanvisning Please read this manual carefully before installing and save the manual for future reference and product warranty Users manual Wood s DSC 90ES ...

Страница 2: ...ment A dehumidifier with high performance creates a good healthy humidity level and for greatest efficiency the doors and windows of rooms that are being dehumidified should be kept closed Wood s dehumidifiers remove odours dries wood and remove moisture from sportswear out doors equipment A dehumidifier may be used in cellars washrooms garages crawl spaces caravans summer hous es and on boats If ...

Страница 3: ... 8 Operating Instructions 9 Maintenance 10 Dehumidifier Storage 11 Ducted Applications 12 Troubleshooting 13 Svenska Introduktion 14 Hög luftfuktighet 14 Placering av avfuktare 14 Säkerhetsföreskrifter 15 Identifiering 16 Elförsörjning 16 Installation 16 Kontrollpanel 17 Indikeringsljus 18 Fjärrmanövrering 19 Operativa instruktioner 20 Varningar 21 Rengöring 22 Installera luftslang 23 Felsökning 2...

Страница 4: ...ere is a risk that the water will flood the dehumidifier it should be thoroughly dried before re connecting to power and reboot To ensure proper operation neither the inlet nor the outlet should be placed against a wall The inlet requires a minimum of 12 clearance and the outlet requires 36 distance from the wall The best option for proper airflow in the room is to dehumidly blow away from a wall ...

Страница 5: ...s an evaporator coil which is cooler than the dew point air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Warning Do not install your dehumidifier in a corrosive environment Some liquid vapor barriers dry via solvent evaporation Always make sure that barrier is completely dry and area is throughl...

Страница 6: ... use the arrow keys to set the humidity below 36 At this point the Co nt light should illuminate green on the display board to indicate you have successfully switched to continuous mode The display screen will show CO When set to continuous the dehumidifier will run constantly regardless of the humidity level until you turn the unit off or switch back to normal humidistat operation simply move the...

Страница 7: ...ompressor Light When the compressor light glows red it indicates the compressor has been initiated but is currently warming up Once the compressor light switches to green it indicates the compressor is in working status 5 Unit indicator light When the unit indicator light is red it illustrates the dehumidifier is in unit mode While in unit mode the dehumidifier will use it s built in humidity sens...

Страница 8: ...difier is installed in your crawl space the remote could be mounted in your living space or garage This provides you with an easy way to monitor the dehumidifier 1 On Off Power Button Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the Up and Down arrow buttons to adjust the humidity level 3 Mode Use th...

Страница 9: ...e dehumidifier Do not unplug the power cord directly to force the machine to stop working 4 Water drainage The DSC 90ES has both a auto drainage function and a manual drainage function During normal operation the DSC 90ES will automatically drain as required If you would like to store the machine or drain water at will you should press the drain button to drain the water from the pump reservoir Th...

Страница 10: ...m once a year Cleaning the machine body Use a soft moist cloth to clean exterior of unit Do not use any soap or solvents Cleaning the filter 1 Unplug the unit 2 Slide out the filter 3 Clean the filter mesh by vacuuming or washing with warm water no soap or solvents 4 Be sure the filter is completely dry before reinserting Coil Maintenance Once per year clean the coils with an approved coil cleaner...

Страница 11: ... reservoir by unscrewing the screw Wipe reservoir clean with a paper towel 4 Mix a16 oz solution of either 1 oz bleach 15 oz water or 4 oz white vinegar 12 oz water 5 Fill the pump reservoar with cleansing solution 6 Reassemble pump then use manual drain button to flush mixture through discharge tubing 7 Pour same cleaning solution slowly into drain tray under evaportor coils and let it clean hose...

Страница 12: ...t 12 return ducting it may be helpful to 1 Remove inlet grille from end cap 2 Connect duct to inlet grille 3 Reconnect inlet grille to end cap Note The supply duct adapter is standard on all units Removing Duct Adapter If it is necessary to remove the adapter place hand at bottom of the adapter and use your hands to lift out and down This will re move the cover hooks from the machine Flex Duct Ins...

Страница 13: ...t or outlet is blocked Clear the blockage from air inlet or air outlet Trouble Code E 4 Pump has failed Verify that the pump is working if so unplug the unit for two minutes then restart Loud Noise Machine is not level Move the dehumidifier to flat firm ground Filter mesh is clogged Clean the filter mes according to instructions listed in manual Trouble code HI or LO Room temperatur over 40 C or b...

Страница 14: ...ker en kondensering varvid vattendroppar bildas Vid hög luftfuktighet kan luften bli unken då kan det bil das mögel vilket gör att huset och dess inredning tar skada En sådan miljö kan leda till sjukdomar hos dem som bor i huset då bl a kvalster trivs i en fuktig miljö En avfuktare med hög prestanda skapar en bra och hälsosam fuk tighetsnivå För att uppnå bästa effekt ska dörrar och fönster i de r...

Страница 15: ... att säkerställa korrekt drift ska varken inloppet eller utloppet placeras mot en vägg Inlop pet kräver minst 30 cm och utloppet kräver minst 90cm i avstånd till vägg Det bästa alternativet för korrekt luftströmmning i rummet är att avfuktaren blåser bort från en vägg och inloppsluften parallellt med en vägg Sätt inte in dina fingrar eller föremål i luftintaget eller luftutblåset Allt arbete på av...

Страница 16: ...r torkar via lösningsmedels förån gare Se alltid till att barriären är helt torr och området är väl ventilerat innan du installerar avfuktaren Steg 1 Placera avfuktaren på en jämn yta Om inte avfuktaren är placerad på en jämn eller rak yta kan kompressorn ta skada Steg 2 Installera vattenslangen Anslut den medföljande slangen till avfuktaren och för den andra änden till ett avlopp Wood s DSC 90ES ...

Страница 17: ...ning av maskinen tryck ned Drain knappen för att avlägsna vatten från den integrerade pumpbehållaren 6 Varning pump problem När pumpbehållarens vattennivå är för hög så aktiveras sensorn för högt vatten för att förhindra översvämmning När detta inträffar så stoppar avfuktaren kompressorn automatiskt och displayen visar E4 Efter 1 minuts uppehåll så stängs fläktmotorn av och maskinen fungerar inte ...

Страница 18: ... lyser rött betyder det att enheten är i auto avfrostningsläge och rensar kondensorn från vatten och is uppbyggnda 4 Kompressor lampa När kompressor lampan lyser rött indikerar det att kompressorn har startats men är ej i full arbetsgång När kompressorlampan växlar till grönt indikerar den att kompressorn är i drift 5 Enhetsindikator lampa När enhets indikator lampan är röd visar den att avfuktare...

Страница 19: ... igen för att stänga av maskinen 2 Pil Upp Pil Ned Använd knappen för Upp och Ned pilen för att justera fuktnivån 3 Program Mode Använd programknappen för att växla mellan avfuktning och kulvert användning Symbolen på displayen indikerar att sensorn på fjärrkontrollen används Symbolen på displayen indikerar att sensorn på avfuktaren används 4 Temperatur Tryck på temperaturknappen för att visa den ...

Страница 20: ...tanna 4 Vatten dränering DSC 90ES har både en automatisk dränerings funktion och en manuell dräneringsfunktion Under normal drift dräneras DSC 90ES automatiskt efter behov Om du vill lagra maskinen eller dränera vatten i viloläge bör du trycka på dränerings knappen för att tömma vattnet från pumpbehållaren Tömmningen kommer att fungera i 15 sekunder varje gång knappen trycks in Det kan vara nödvän...

Страница 21: ...g 1 Lossa filtret 2 Rengör filtret Torka av filtret eller rengör det i varmt vatten och lite diskmedel Låt filtret torka helt innan du sätter tillbaks det 3 Sätt tillbaka filtret Förvaring Om du inte kommer använda avfuktaren under en längre tid vänligen följ nedan instruktioner 1 Tryck på DRAIN för att tömma ut vattnet från avfuktaren 2 Samla ihop strömsladden 3 Rengör filtret 4 Förvara avfuktare...

Страница 22: ... locket från pumpen genom att skruva loss skruven Torka behållaren med en trasa 4 Blanda en lösning av 1 2 dl vitvinsvinäger 3 5 dl vatten 5 Fyll pumptanken med rengöringslösning 6 Återmontera pumpen tryck sedan på tömnings knappen för att spola lösningen genom systemet 7 Häll rengöringslösningen långsamt till droppbrickan som är placerad under kylslingorna Slangen rengörs då mellan droppbrickan o...

Страница 23: ...för att lyfta upp och ner Rör installation För att installera adaptern plac era hakarna i adaptern i hålen på enheten och tryck uppåt från botten av adaptern NOTE Om sladden är skadad måste den er stattes av tillverkaren dess servicerep resentant eller liknande kvalificerade personer Rotera flexslangen motsols Borttagning av flexslangen Rotera flesslangen medsols ...

Страница 24: ... underlag Är filtret blockerat Rengör filtret Felkod E1 När displayen visar E1 är det fel på fuktighetssensorn eller så är den inte korrekt inkopplad Byt ut fuktighetssensorn eller kontrol lera att den är korrekt inkopplad Felkod E2 När displayen visar E2 är det prob lem med vattenpumpen Byt ut eller reparera vattenpumpen Felkod LED lampan blinkar När lampan blinkar rött är det fel på temperaturse...

Страница 25: ...Contact Wood s is marketed and distributed by TES Scandinavia AB Maskingatan 2 441 39 Alingsås Sweden 46 0 31 761 36 10 www woodseurope com info woods se Bruksanvisning SE ...

Отзывы: