13
Operating instructions
GB
Troubleshooting
If you are having trouble with your dehumidifier, please refer to below trouble shooting.
Symtom
Cause
Solution
Machine won´t run.
Power
supply
Verify that there is power to the outlet
and that the plug is properly installed
in outlet.
Room
temperature
over
40°C (dis-
playHI)
or
below
0° C(display LO)
The unit is outside the operating
temperature range. Modify the room
conditions so the temperature is
between 0°- 40°C and operation will
commence.
Low Air Flow
Air Filter is clogged.
Clean the filter mesh according to
instructions listed in the manual.
Air
inlet
or
outlet
is blocked.
Clear
the
blockage
from
air
inlet
or
air
outlet
Trouble Code E:4
Pump has failed
Verify that the pump is working if so,
unplug the unit for two minutes, then
restart
Loud Noise
Machine
is not level.
Move the dehumidifier to flat, firm
ground.
Filter mesh is clogged.
Clean the filter mes according to
instructions listed in manual.
Trouble
code
HI or LO
Room temperatur over 40°C or below
0°C (Display LO).
The unit is outside the operating
temperature range. Modify the room
conditions so the temperature is
b-0°-40°C and operation will
commence. IF room is not out of tem-
eratur range, replace faulty sensor.
TECHNICAL DATA
Power Supply
220/230V~ / 50Hz
Power(W)
1350- 1550
Water Tank
Both Auto and Manual Drainage
Weight(kg)
36 Kg
Package size(w*D*H)
630*350*400 mm
Barcode